background image

Features

  

  

Service     Manual

Special No.: SMHLP140E-01

Edition: 2007-4-10

 Antibacterial drying, easy and safe

 PTC heating, rapid temperature rise

 Automatic thermo-limiting, safe and easy 

 No outdoor air drying, avoiding dust pollution

 Computerised control, atuo drying

Tumble Exhaust Type Clothes Dryer

HLP140E

Models:

Version:00.00

Summary of Contents for HLP140E - 2.6 cu. Ft. Portable Vented Electric Dryer

Page 1: ...07 4 10 Antibacterial drying easy and safe PTC heating rapid temperature rise Automatic thermo limiting safe and easy No outdoor air drying avoiding dust pollution Computerised control atuo drying Tumble Exhaust Type Clothes Dryer HLP140E Models Version 00 00 ...

Page 2: ...Product introduction and main features 2 Specification and net dimension 3 Important Safeguards 4 Operating your dryer 6 Parts and structure 10 Wiring diagram 10 Wall Mounting Instructions 11 Maintenance 13 Troubleshooting 14 Maintenance service and trouble shooting 15 ...

Page 3: ... dryer drum and impeller driven by the motor The heating device is a positive temperature coefficient PTC semi conductor heater of self control of temperature and high safety provided with a 70 thermo limiter At the air inlet a filter screen is provided to keep air clean and free of impurities 2 Drum portion The support plate front of the drum is installed on the dryer cabinet with 6 connectors Aw...

Page 4: ...xhaust type cold air drying and hot air drying Auto dry Normal heavey delicate can be choosed Timed dry refer to the operating instructions 24kg 3 5kg Safety device a Safety device b Motor overload protector c Thermostat d Over temperature circuit breaker A Overall dimensions Product net weight Drying mode 3 NET DIMENSION Unit mm Tumble Exhaust Type Clothes Dryer Model HLP140E ...

Page 5: ...ers or products to eliminate static unless recommended by the manufacturer of the fabric softener or product 10 Do not use heat to dry articles containing foam rubber or similarly textured rubber like materials 11 Clean lint screen before or after each load 12 Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint dust and dirt When using electrical ...

Page 6: ...y plugged or unplugged by hand It must be unplugged during power blackout moving not in use or cleaning Do not plug or unplug the power cord with wet hands 27 Always disconnect dryer from electrical supply before attempting any service Disconnect power cord by grasping the plug not the cord 28 Do not block the exhaust vent when dryer operating to prevent it from overheating or other dangers 29 Do ...

Page 7: ...match as well as sharp metal items like coin hair clip and safety pin maybe mixed with the clothes and in pockets Clothes with zipper or fastener shall be put into your dryer inside out with zipper zipped and fastener buckled Do not tumble dry Do not tumble dry Hang to dry Hang to dry Drip dry Drip dry Dry flat Dry flat Dry in the shade Dry in the shade Please put clothes into the drum Avoid cloth...

Page 8: ...heating The temperature decreases Cycle End The cycle is completed Clean Lint Remind you clean the lint in time each time you dry your clothes Normal Normal drying Heavy Huge and heavy garments Delicate Low level heat resistance Cycle button Timed Dry You can set the drying time as required Possible cycle PowerOn Off button Start Pause button Press in the PowerOn Off button to connectthe power con...

Page 9: ...Off Temp Tumble Exhaust Type Clothes Dryer Model HLP140E Press in the Start Pause button Make sure thefront door isproperly closed beforeyou press inthe Start Pause button otherwise theclothes dryer won tstart and givean alarm The machine willstop to workif the frontdoor is openedin middle ofoperation including heater andengine It willcontinue to workafter pressing the Start Pause button when the ...

Page 10: ...r If you want to take out clothes in the middle of high temperature operation please firstly make the dyer cool and then take out the clothes Under normal condition static electricity comes as a result of garments made from chemical fiber rubbing against each other 5 Pull out the plug When pull out the plug please hold the plug top rather than dragging the line in case the inner electric wire was ...

Page 11: ...r Gray Red Blue Yellow Temperature controller White WIRING DIAGRAM 10 Tumble Exhaust Type Clothes Dryer Model HLP140E Drum Exhaust shroud Air intake shroud Control panel Window Power cord Exhaust vent Back cover Cabinet Door gasket Door Red Black Black Yellow Yellow Yellow White White Door switch Temperature sensor ...

Page 12: ...11 Tumble Exhaust Type Clothes Dryer Model HLP140E ...

Page 13: ...12 Tumble Exhaust Type Clothes Dryer Model HLP140E Hoop around the joint of the exhaust pipe and the dryer ...

Page 14: ...l And dry it in the air absolutely before use Take care not to damage the filters See fig 2 3 Re installing the Filter Reinstall in the reverse order align the recess in the centre of the filters with the spigot in the centre of the drum and ensure that it is fitted firmly as shown in figure 3 Note The filter fixed in the bottom of the drum should also be cleaned with a soft brush Do not use exces...

Page 15: ...nough after the machine stops work Is the front door properly shut Have the garments got tangled up Separate the tangled up garments and make them dried Are the easy hard dry clothes not sorted Select out the garments that not dry to make them dried Select out the garments that not dry to make them dried Is the dryer standing position narrow and stuffy Place the machine in a position that ventilat...

Page 16: ...rum Replace the wedge belt Connect the power and close the door Yes Check if the motor is OK Yes Check if the wire module is OK Replace the motor No Check if the capacitor is OK Replace the capacitor No Yes MAINTENANCE SERVICE AND TROUBLE SHOOTING 15 Tumble Exhaust Type Clothes Dryer Model HLP140E Check the drying time 150 90 60 flash at the same time No No Yes Protective program put the power on ...

Page 17: ...ce thermostat and protecting device Replace PTC heating element Infinite resistance Yes Clean air outlet filter adjust air outlet position Check if circular belt releasing or broken fix or replace the belt No No Yes Yes No Yes Check if wire module is OK No Check if air outlet and exhaust duct are clogged Clean air inlet filter Check if air inlet filter clogged No Yes Yes Re connect firmly No MAINT...

Page 18: ... tension spring If it is loose screws tightening exhaust du ct on the rear plate or screws fastened on impeller cover scratching drum If anti wear felt falls down and causes circular belt striking the drum Connect power and close the door Run the dryer Yes Adjust machine location and feet If it is the machine body resonance or not on level No No lubricant on the air impeller No MAINTENANCE SERVICE...

Page 19: ...Group Sincere Forever ...