– 29 –
J101
Board Line Voltage
J501
Damper (Pin 1: Open Switched Line) (Pin 2: Neutral) (Pin 3: Closed Switched Line)
J502
Damper (Pin 1: COM Switched Line)
J506
AC Voltage to Heater, AC Voltage to Inverter
J512
AC Voltage Out to Drain Pump, AC Voltage Out to Fan, Damper Detection (Pin 5)
J513
AC Voltage Out to Door Lock Assembly
J514
AC Voltage Out to Water Valves
J601
DC Voltage Out to Inverter Board and Communication Between Main and Inverter Boards
J602
DC Out to RJ45
J615
DC Out to User Interface and Communication Between Main Board and User Interface
J701
DC Out to Thermistor
J702
DC Voltage Out to Reed Switch
J801
DC Voltage Out to Tub Light
J901
DC Voltage Out to Accelerometer and Communication Between Main Board
Main Board
NOTE: Wire colors in the following pictures may not be the same as the machine being serviced.
J602
J502
Wi-Fi
Board
J801
J101
J513
J501
J615
J506
J701
J702
J512
J514
J601
Pressure
Sensor
To Wi-Fi
Board
J901