ES10V-M1

ES15V-M1

ES25V-M1

Spa Water Heater

User's Manual

0040502334

V

Please read this manual before usage.

Retain it for future reference.

Safety warning (Read carefully before use)

Pre-safe Expert

Check if the ammeter and the diameter 

of the wires are in accordance with 

the rated current of the water heater. 

If necessary, please have it checked by 

an experienced electrician.

This water heater is available for AC 

230V/50Hz power.

Be sure to use independent socket 

and earth it reliably, and socket 

quality shall conform to the national 

standard requirements.

Set the power socket of the water 

heater at the dry position away from 

spraying water. Do not plug/unplug 

with wet hands.

After installation, be sure to f

 

ill the 

heater completely with water before 

switching on the power in the f

 

irst 

usage. Children must take a bath 

under the supervision of adult.

In opening and closing the water 

valve, do not point the showerhead 

toward the human body. Otherwise 

it may hurt by the spraying hot water.

During winter in a cold area, if the heater 

is idle for a long period, please pull the 

handle of the safety valve to discharge the 

water. Otherwise it may freeze inside the 

water heater and cause damage.

In case the power cord of the water 

heater is damaged, be sure to have it 

replaced by after service technicians 

manufacturer.

Do not set at place that is too cold 

and may freeze.

Do not set at outdoor places.

Do not use as f

 

loor standing 

appliances.

Please mount it to f

 

irm and reliable 

wall.

Do not install to places without 

sewage.

Connect the drain hose to the inlet 

of the sewer to avoid polluting by 

splashing.

Never do that.

Be sure to act as per instructions.

The product adopts the patented  "Safe Care"  technology of our company. As long as 

product adopts civil power supply, even if the earthing wire is electrif

 

ied by mistake, the  

"Safe Care" technology still can block dangerous electricity, and ensure your personal 

safety. But if you f

 

ind any perceptible current, please disconnect the power and contact 

after service department for maintenance. Do not disassemble by yourself.
The original pipeline of the water heater is an organic part of  "Safe Care" . Do not remove 

it by yourself. Otherwise we will not take responsibility for injury and loss caused by the 

safety danger occurring.

This mark is the designation for Pre-safe Expert of Haier Water Heater 

Company, which indicates the use of the company's patented technology 

inside the product. It ensures you a safe bath while monitoring whether 

your house ground wire is live or not all the time. If this mark is lit, it 

indicates your house ground wire was come live (poor grounding and 

live). In this case, please immediately stop use and disconnect the power, 

and remember not to touch any electric appliance in your house. At the 

same time, immediately contact after-sales service and your property 

 

Pre-safe Expert will become the electric safeguard for your family.

See to the physical for the appearance, color or pattem.

Mark of Haier Safe        

Water Heater

Electric circuit diagram

Installation 

 Usage

Installation must be made by installers of, or designated by, our company after-service 

department. The water heater shall be wall-mounted.
Make 2 holes 

Φ

12mm, 65mm deep in wall with an impact drill according to the drawing of 

the external dimensions.  

Take out all accessories in packaging liner, unpack one hook, sleeve the ring end of the 

connection lines among the accessories into the hook tightening end and assemble the hook 

well. Afterwards, insert and f

 

ix two hooks into the holes (wherein the hook with connection 

lines is f

 

ixed in the right hole). Lift the water heater and hang it with wall rack corresponding to 

the two hooks. insert the connection spacer led from the rear shell wall rack of the heater into 

the connection terminal of the line on the hook (See Figure 2). Install accessories such as safety 

valve as shown in Figure 3. Do use sealing compound to prevent water leakage.
To facilitate installation and removal, it is suggested a G1/2 movable nut be f

 

itted at appropriate 

locations on inlet and outlet pipes respectively. Find the location requiring hot water supply. 

Connect inlet pipe, outlet pipe and city water pipe respectively to the use point for hot water. 

Note: The hot water pipe shall not be too long to reduce heat losses.
Please reserve some space in installation for the future maintenance.

Installation

Live wire (brown)

High temperature limiter
Thermostat
Heating indicator
Heating element

Grounding wire (yellow/green)

Null line (blue)

Packing list

Electric water 

heater (Set)

Safety valve 

Drain hose 

(Unit)

Expansion 

hook (PCS)

User's manual 

(Copy)

Connecting 

line (PCS)

ES10V-M1

ES10V-M2

1

1

2

1

1

1

1

2

1

1

1

1

2

1

1

1

1

2

1

1

ES15V-M1

ES15V-M2

ES25V-M1

ES25V-M2

 

Name

Quantity
Model

CSH09H0302_090818.indd   1

8/28/2009   9:59:51 AM

ES35V-M1

ES10V-M2

ES15V-M2

ES25V-M2

ES35V-M2

Reviews: