Failure diagnosis
Upon abnormal operation:
Please read the User s Manual
attached with the indoor unit before asking for
repairing. You may contact the after-sales technicians after careful checkup.
When faults arise, the symbol
appears along with the error code.
The central controller faults corresponding to error codes are given in the
following list (including air conditioner faults and group control network faults):
Code
Meaning
None (normal operation)
Fault with indoor ambient temperature sensor
Fault with indoor tube temperature sensor
Indoor heating overload protection
Indoor cooling icing (overload) protection
Indoor & outdoor communication error
Communication fault between panel (wire controller) and indoor unit
(air conditioner indication, central controller shows 30)
Module fault (PFC protection
DC)
No load
Compressor overheating
Abnormal CT current
Fault with outdoor ambient temperature sensor
Fault with outdoor heat exchanger (tube temperature) sensor
Protection of supply overvoltage or undervoltage
High voltage protection
--- Fault with outdoor evaporator sensor
--- Cooling overload
EEPROM fault
Fault with outdoor return gas sensor
Fault with compressor sensor
--- Fault with indoor evaporator sensor
Drain system failure
Power supply 3-phase fault (phase lack or mistake)
Humidity sensor malfunction
Indoor fan failure (fan overcurernt, fan IPM protection, fan Holtz
element fault)
Blank
Low voltage protection
--- Electronic expansion valve failure
--- Dust remover screen needs cleaning
Insufficient refrigerant
Abnormal communication between monitor and air conditioner
Abnormal communication between monitor and bus
Outdoor fan failure (fan overcurernt, fan IPM protection, fan Holtz
element fault)