Model 410
Owner’s Manual
6/16/2014
32
Assembly and Parts, Cont.
Drain End Cap Assembly
Figure 25: Drain End Cap Assembly
Part #
Description
Quantity
1
93808
O-Ring
1
2
90268
Drain End Cap
1
3
H2086-X.X* Drain Line Flow Control
1
4
90267
Retainer
1
90614-X.X* Entire Assembly (all the above parts)
1
* Must specify drain line flow control size. “XX” indicates the backwash flow rate in gpm. Example: 90614-2.4.
90268 Drain End Cap
The Drain End Cap (90268) seals the left opening on the Main Valve Body. The opening is sealed
with an O-Ring used as axial or “face” seal. The O-Ring sits in a groove in the End Cap. This
groove must be free of defects such as pits or scratches and also free of debris. When
assembling the End Cap to the Valve Body, care should be taken to make sure that the O-Ring
stays in the groove in the End Cap. If misaligned, the O-Ring can become pinched and leak.
H2086 Drain Line
Flow Control
The Drain Line Flow Control (DLFC) maintains a constant (plus or minus 10%) backwash flow rate
at varying pressures. Care should be taken when replacing DLFCs to ensure that the correct rate
is being used for a particular model. Refer to
Specifications
. When assembling the flow control,
ensure that the rounded (radiused) side of the hole faces in toward the water flow.
H2086-2.4*
H2086-3.0*
90267 Retainer
The Retainer (90267) holds the backwash Flow Control (H2086) in place. One side is smooth and
the other has a groove for a screwdriver. When assembling the retainer to the Drain End Cap
(90268), the retainer should be screwed in until it stops. If the retainer is not fully engaged, the
Flow Control may not function properly.
Summary of Contents for MicroBoss II
Page 3: ......
Page 19: ...Model 410 Owner s Manual 6 16 2014 18 Figure 15 Remplir le bac à saumure de sel ...
Page 38: ...Notes ...