SECTION 3 –
OPERATING YOUR NTB
3-16
2. On the “NTB Adjustments” screen, press
EDIT (next to NTB Override Timer).
3. Enter desired value (ranging from 100 to
10,000 milliseconds), then press OK.
4. Press OK.
FLOAT OPERATION - 60’
NTB
Float operation allows the NTB to raise up
and down while riding through the field to
avoid machine damage due to uneven
ground.
Float operation may be activated using
various methods. In all options, Float must be
enabled through the Machine Display and the
machine must be in Field Mode.
Master Spray Switch
The Master Spray Switch (located on the
back side of the Hydrostatic Drive Control
Handle) controls both the solution pump and
the Float “Down” functions when Float is
activated.
1. Press the Field/Road Button (located on
the Machine Display - Home Page) and
change the machine’s drive state to
FIELD mode.
NOTE: The selected drive state will
illuminate.
NOTE: The machine’s drive state cannot be
changed unless the Hydrostatic Drive
Control Handle is in the NEUTRAL
position.
2. Press the Float Button (located on the
Machine Display - Auxiliary Controls
Page) to enable Float operation.
NOTICE
Ensure Float operation is enabled when
operating the NTB. Failure to comply
may result in property damage.
NTB Setup Button
(Located on the Machine Display -
Settings Page)
NTB Adjustments Screen
Field/Road Button
(Located on the Machine Display