SECTION 3 –
OPERATING YOUR NTB
3-6
UNFOLD/FOLD PROCEDURE
- 60’ NTB
NOTE: Refer to the “60’ NTB Layout”
illustration provided in Section 1 -
Introduction elsewhere in this
manual to aid in identifying the
various sections of the NTB.
Unfold Nitrogen Toolbar
(from storage position)
1. Ensure the Hydrostatic Drive Control
Handle is in the NEUTRAL position.
2. Press the Field/Road Button (located on
the Machine Display - Home Page) and
change the machine’s drive state to
ROAD mode.
NOTE: The selected drive state will
illuminate.
Left and Right Boom/NTB Switches
(Located on the Hydrostatic
Drive Control Handle)
-Typical View
• Left Boom UP
• Left
Boom IN
• Left Boom OUT
• Left Boom
DOWN
• Right Boom UP
• Right Boom
OUT
• Right Boom IN
• Right Boom
DOWN
Left and Right Boom/
NTB Switch Orientation
-Typical View
WARNING
Before proceeding, check the area
around the machine for bystanders,
overhead objects, and power lines.
Failure to comply may result in serious
injury or death.
Hydrostatic Drive Control Handle
-Typical View