SECTION 2 –
SAFETY AND PRECAUTIONS
2-6
When the E-Stop Switch is depressed, it
locks in position and removes the ignition
signal to shut down the engine. To reset the
E-Stop Switch, turn the switch in the direction
of the arrows (located on the face of the
button).
OPERATOR PRESENCE
SWITCH (OPS)
The Operator Presence Switch (located
inside the operator’s seat) protects the
operator from exposure to moving parts or
hazards when operating the detasseler
cutter heads and quad pullers.
This safety feature introduces an
electrical interlock that ensures that when the
operator is out of the operator’s seat, the
operation of these functions have stopped.
This is achieved by using the OPS to prevent
the detasseler assemblies from operating if
the operator is not seated in the operator’s
seat for three (3) seconds.
To Reactivate the Cutter Heads and Quad
Pullers:
NOTE: The operator must be seated in the
operator’s seat before reactivating
the detasseling heads.
•
Press the Master Detasseler Switch
(located on the side console) in the
DOWN (Off) position.
•
Return the engine to idle.
•
Press the Master Detasseler Switch in
the UP (On) position for all functions to
resume.
E-Stop Switch
(Located near the side console)
-Typical View
Operator Presence Switch
(Located inside the operator’s seat)
-Typical View
Master Detasseler Switch
(Located on the side console)
-Typical View
Summary of Contents for 204SP