1
Installation and Maintenance Manual, Compact CBP
x
10
α≤
± °
25
To be glued with
Loc-Tite 601
3.1.5 Mounting the reaction point
Make sure that the foundation
can withstand the forces from
the torque arm.
Fig. 3.17
Fig. 3.16 Mounting of pivoted attachment
x = ± mm (0,079) misalignment in installation.
x
≤
±15 mm (0,59) movement when in use.
Bearing fitted
with Loc-Tite 601
Installation
Fig. 3.18
Alternative
position
Steel:
EN 1011S55N
DIN St E9
BS 460 Grade 50 C
DANGER ZONE
In case of failure of
torque arm installation
Note: The toggle bearing must
be dismounted during welding.
Protected against corrosion, after welding.