hager TRE53 Series User Instructions Download Page 1

15 min

s

5 min

auto

-

+

lux

test

30

8 m  

(

α

 200°)

8 m  

(

α

 200°)

6 m  

(

α

 140°)

6 m  

(

α

 140°)

α

1

6T 7973-02a

6T 7973-02a

Warning  :

This device is to be installed only by a 
professional electrician fitter according to
local applicable installation standards. 

Test and validation of detection
zone

Set potentiometer 

2

to Test mode. 

The Test mode is available for 3 minutes time
and does not take brightness level into
account. 
Each detected movement turns LED 

A

on for 2

seconds. 
The associated receiver is not under control.
After 3 minutes without detection, the product
is set back to auto mode. 
Limitation of detection zone :
You can limit the detection zone using the
shutters supplied or by inclining the head.

O

The test mode is available only once the
product has been configured.

Mounting

Projection or ceiling mount :
- Fix the wall plate using the supplied screws. 
- Clip the detector onto the wall plate
- Tighten the screws to close. 

For angle mounting, the wall fixing plate is 
fitted between the accessory and
the detector.

Precautions for installation

Product Description and working
principles

This detector allows remote control of one 
or more receivers for a given time when a
movement is detected in its detection zone. 
This product can be used in two types of
configuration: one detector controls
one/several receiver(s); several transmitters
control the receiver(s). 

Operation

The receiver(s) is(are) under control as soon as
the brightness level as set by potentiometer 

2

is considered too low and a movement is
detected. 

2 types of operation are possible: 

- Only one detector controls the receiver(s) :
Upon detection, the receiver remains activated
for the time set by potentiometer 

1

. Before

starting configuration, set the desired delay on
potentiometer 

1

Follow the configuration procedure as
explained in the Configuration Instructions
supplied with the receiver and select the
"Remote control switch” function. 

- Several detectors control the receiver(s) :
Après détection, le récepteur reste activé 
Upon detection, the receiver remains activated
for the time set for the configuration on the
receiver. 

Before starting configuration, set
potentiometer 

1

to "impulse" position

.

Follow the configuration procedure as
explained in the Configuration Instructions
supplied with the receiver and select the
"Remote control switch" function. 

If LED 

A

flashes quickly during configuration,

the position of potentiometer 

1

is not 

compatible with the selected function. 

Factory return

Keep push-button 

J

depressed until LED

cfg

(flashes (>10s), and then release it.

LED 

cfg 

is turned off when factory return is

completed.
This operation causes full delete of product
configuration in any configuration mode. 
After factory return, wait 15s before starting
configuration.

Configuration (button 

J

)

These detectors can be configured in 3 different
ways :
• 

: tool-free configuration (using product

pushbuttons and LEDs), see User's Instructions
6T7952 supplied with the product. 

• TX100/B V2.6.0 or above : 

description of product functions available from
the Manufacturer.

• ETS3 or via TR131 : database and description of

application software available from the
Manufacturer.

Configuration by TX100 or ETS

Set the product in configuration mode by pressing

J

button once during the teaching session of

TX100 or for addressing with TR131 in ETS.

O

Product factory return is required to change
the configuration mode. 

quick

link

Description  

Detection zone

TRE51., TRE53.

Installation

Adjustments

Shutters

Angle fixing support 

Optimal installation height is 2.5m. 
The detection zone shall remain free of obstacle. 

8 m

16 m

2,5 m

0,5 m

16 m

4 m

LED

A

LED

B

Delay
(lighting time)

Brightness

level 

Sensitivity
(change 
of range)

§

Motion Detectors  
220° solar

User instructions

¨

Action

Adjustments 

Potentiometer 

Use Auto (factory)
settings 
to set automatic
lighting turn-on for 
a given time.

Auto Settings

Put the Lux potentiometer on

auto test

”.

The settings are predefined :
Lux = 

(operating at night only)
time = 3 min,
sensitivity = max

auto

lux

test

Turn automatic 
lighting on for 
a given time.

Installer settings

15 min

30 s

5 min

auto

-

+

lux

test

Control a timer,
a chime, etc. 

Impulse 

Auto settings are usable with
time = 1s.
(cannot be changed).

15 min

s

5 min

auto

-

+

lux

test

30

Test and confirm
detection zone. 

Test mode

Move the potentiometer 

to “

auto test

” 

auto

lux

test

auto

lux

test

Adjust sensitivity

Allows setting the range
to avoid disturbance.

-

+

DETECTORS 220°

TRE510

White

TRE511

Anthracite

TRE530

White

TRE531

Anthracite

Hereby, hager Controls, declares that this motion detector
output is in compliance with the essential requirements
and other relevant provisions of Directive 1999/5/EC.

The CE declaration can be consulted on the site :

www.hagergroup.net

Usable in all Europe

and in Switzerland

For optimum detection conditions, please follow these recommendations :
- Keep the detector protected from solar radiation and bad weather, as it is sensitive to these

conditions. 

- Maintain 1m distance between the light source and the detector and keep the detector out of the

light source.

1

2

IP55

+ 90°/- 30°

+/-80°

Wall fixing plate

Adjustment potentiometers

Directional detection head

Vertical adjustment

ACCESSORY FOR

ANGLE FIXING

EE855

White

EE856

Anthracite

52125

White

52126

Anthracite

RF

TP

230V~

Bus

30 V

Button

cfg

cfg

LED C

Button 

J

V2.6.0

Reviews: