This programmable ambient thermostat has been designed to bring you comfort and energy economy.
It allows you to program and regulate your heating system at 4 temperature levels :
- Comfort
: this is the temperature you desire during the hours you are present.
- Comfort 2
: 2nd temperature level that you desire during the time you are present.
- Eco : this is the temperature you desire during short absences or at night.
- Frost protection
: this is the guaranteed minimum temperature during your prolonged absences.
It protects your accommodation against the dangers of frost.
It also enables you to program and regulate your air conditioning at 2 temperature levels :
- Comfort
: this is the temperature you desire during the hours you are present.
- Eco : this is the temperature you desire during short absences or at night.
1
6T 7786-02B
EK530
Product description
Context key for
menu
access
Context key for mode access holidays
Context key to access the temporary
override
Confirmation key
OK
Adjustment keys
+
and
-
Indicator for days of the week
Automatic mode/manual mode
(thermostat without program)
Temperature set-points adjustment
Standby
Heating/Air-con selector
Programming/program selection
Time and date adjustment
Adjustment of settings
Ambient temperature
Heating or air conditioning indicator
Current mode (heating or air conditioning)
Current setting (
, , , )
Temperature of current setting
Telephonic remote control
Profile of today’s program
Current time
ok
–
+
§
Programmable ambient
thermostat, mains, weekly
User instructions
ok
–
+
Electrical installation and connections
To guarantee its ambient temperature-regulation
function, the thermostat should be installed around
1.3 m above the ground, on an interior wall and
away from direct sunlight or any heat source such
as a television, lamp, radiator, draft, chimney, etc.
Fix the thermostat onto the flush-mounted casing or
in the slot without a casing intended for this purpose.
For optimum quality temperature regulation, seal
the flush-mounted casing or the electrical duct.
1. Separate the product from the wall-mounted
base, by pushing on the button located under
the base.
2. Open the flap with the help of a screwdriver and
attach the wall-mounted base using the screws.
3. Next, pass the electrical cables into the holes
intended for this purpose.
4. Connect the product according to the wiring
diagram opposite.
This product must be installed according
to the local installation standards in force.
TOP
–
+
ok
1
2
TOP
TOP
1 2 3
1 2 3
4 - 5 6 7 8 9
N
L
2A
6A
telephonic
remote control
(ref. 61123, 61124)
external
probe
(ref. 25190)
1 2 3
input
from remote ambient thermostat
telephonic
remote control
(ref. 61123, 61124)
external probe
(ref. 25190)
1 2 3
4 - 5 6 7 8 9
N
L
2A
Connection of the thermostat to a thermostat
input on the boiler
Connection of the thermostat to the thermostat
input of a reversible or irreversible heat pump (HP)
1 2 3
2A
1 2 3
4 - 5 6 7 8 9
N
L
input
from remote ambient thermostat
telephonic
remote control
(ref. 61123, 61124)
external probe
(ref. 25190)
Connection of a heating or air conditioning
circulator
5. Reclose the flap.
6. Clip the front face onto the wall-mounted base.