background image

LINE CONNECTIONS AND SWITCHING

The SE120 is normally wired for use on 12OV AC power

lines, as in the U.S.A. If your line voltage is different, you

will need the special Hafler export power transformer
which accommodates many other line voltages. Be sure

your amplifier is wired for your line voltage before you plug

it in.

The SEl2O’s power switch may be left on, and the

amplifier switched remotely by connecting its line cord to
the preamplifier (or other control center) which provides a

switched AC outlet. Make sure that the control device can
supply a current of 5 amperes to the SE 120, in addition to the

current required by any other switched units. You may

instead connect the amplifier directly to a wall outlet, and
control it with its own front panel power switch.

CONNECTING CABLES

GROUNDING:

INPUT:

Conventional shielded cables, often supplied with pre-

amplifiers, may connect the control center to the amplifier’s
input jacks. Be sure the cables are not frayed or loosely
connected to the plugs, and that the plug’s outer shield
connection is tight on the jack, to avoid hum. If you wish to
install the SE120 more than a few feet from the preampli-
fier, the permissible cable length to avoid loss of high
frequencies is determined by the preamplifier’s output im-

pedance and the internal capacitance of the cable. If the
output impedance is 600 ohms or less, as with Hafler
preamplifiers, and the cable capacitance is less than  50
picofarads per foot, up to 50- feet is acceptable. Ordinary

stereo interconnecting cables often have higher capaci-

tance, however, so a good quality low capacitance shielded

wire should be used. When making long runs, keep the left
and right cables close together, and avoid running them

parallel to power wiring to reduce the likelihood of hum
pickup.

OUTPUT:

The wires which connect the speakers to the amplifier

should be of sufficient size to preserve the SEl2O’s high

damping factor. 

Standard  #18 gauge lamp cord

 is satisfac-

tory for up to 15 feet if your speakers are of 8 ohms or higher

impedance. A heavier gauge (

#16

 or larger) wire should be

used with 4 ohm speakers or 8 ohm speakers at a greater
distance. Special loudspeaker cables which have adequate
thickness to accommodate long runs are usually available

from audio dealers. The SEl2O’s red and black outputs
accept standard banana plug connectors, including the

double ones with 3/4” spacing. These are the most conven-
ient to use if you will be disconnecting the speakers occa-

sionally. The terminals will also clamp 

spade lug, or a bare

wire through the hole in the center post. Be sure there are

no frayed wire ends which could touch adjacent terminals
or the chassis. Tin bare wire ends with solder to secure all

strands.

PHASING:

Consistent phase relationships are important when con-

necting speakers in order to enable full bass reproduction as

well as midrange and high frequency time alignment. To

be sure all speakers in a system are wired in phase to the

amplifier, each ground or - speaker terminal should be

connected to its black ground tenninal on the SE 120 and the

sp terminal to the corresponding red binding post.
Speaker connecting cable identifies one wire from the other

by the color of the wire, or by marking or coloring the

insulation. NOTE: In the special case of monophonic

operation of the SE 120, (described later) different speaker

connections are employed.

The black output terminals of the SE120 are connected

together internally and grounded to the chassis. This
facilitates the use of external devices which use a common
ground connection, such as some headphone junctionboxes.
You must be sure that the ground or shield connection from
such a device goes to a black terminal on the SE1 20.

NOTE: No such connection may be made when the SE120

is connected for bridged mono operation.

CONVENTIONAL STEREO
CONNECTIONS

It is best to make all connections with the SE120

switched off. Each of the stereo speakers connects to one
horizontal pair of red and black outputs, as identified left or

right on back of the SE 120. The input signals connect to the

corresponding input jacks, and the mono/stereo switch
should be set to stereo.

CONNECTIONS FOR MONOPHONIC

OPERATION

When you wish to drive a single loudspeaker with

increased power capability, the SE120 can be operated in
a bridged mode which drives both channels with the same
signal and combines their output to deliver more than 120

watts into 16 ohms. In this arrangement, the speaker is
connected only to the two red output terminals. The left red
terminal is + and the right red terminal is the 

-

 connection.

NO CONNECTIONS MAY  BE MADE TO ANY BLACK

TERMINAL!! Set the Input Mode Selector switch to

mono, and connect the input signal to the left channel input
only. IMPORTANT NOTE: Never use a speaker with an

impedance of less than 8 ohms when operating the SE120

-3-

Summary of Contents for SE120

Page 1: ...THE Hafler SE120 POWER AMPLIFIER SERVICE MANUAL HAFLER A DIVISION OF ROCKFORD CORPORATlON 613 SOUTH ROCKFORD DRIVE TEMPE ARIZONA 85281 ...

Page 2: ...nput Mode Selector This switch will allow the user to specify the input signal to the amplifier A Stereo Mode This allows the right and left channels to reach their designated amplifier channels This mode will deliver more than 60 watts into an 8 ohm load B Mono Mode The SE1 20 can be operated in a bridged mode which drives both channels with the same signal and combines to deliver more than 150 w...

Page 3: ......

Page 4: ... banana plug connectors including the double ones with 3 4 spacing These are the most conven ient to use if you will be disconnecting the speakers occa sionally The terminals will also clamp a spade lug or a bare wire through the hole in the center post Be sure there are no frayed wire ends which could touch adjacent terminals or the chassis Tin bare wire ends with solder to secure all strands PHA...

Page 5: ... of these fails it is usually indicative of a fault which will require professional service Bias current adjustment for the SE 120 needs to be performed in the following manner 1 No signal applied to the input no load on the output of the amplifier 2 Line voltage to the amplifier should be set at the nominal value for the area 3 Adjust one channel at a time 4 With the unit off remove either the or...

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ...0 Polyprcpylene 330 pfd 63Qv 3 Dipped Mica 100 nfd Non Polar Radial 47 pfd 65Cv 3 D ped Mica 220 pfd 75 10 Polypropylene 3pfd O DbpedMka O W1 tid 25 10 Pwene 100 tid 5 u 209 Polar Electrolyric 0 1 mfd lWv 209 Polyester 0 1 mfd 1Wv zn pofyester 0 33 rrfd 16Ov 10 Pe 0 1 rw loOv 20 Pofyester 1 W tid 50 20 PotarIE rotytic CPP m CPP 221 CM 331 CERNP 107 CM470 CPP 221 CM CPP 102 CER 107C CP 104A CP 104A...

Page 11: ...2P3 HWH 134 SM 2103S2 HWH 295 HWH 290 SWH 144 FA LOGO SE120 Cover SE120 SE120 Domestic transformer screw SE120 Export transformer 10 32x1 2hex socket head screw PC 58 board kit SE120 L bracket SE120 Painted heatsink SE1 20 Faceplate SE120 6 1 2 sm hex socket head screw Chassis SE120 10 32x1 2 hex socket head screw Standoff post On off switch SE120overlay lO ...

Page 12: ...OPEN FACE VIEW OF SE120 ll ...