5.52.121.01.01.08
13
DANGER!
Hoists up to 10 t capacity, 4 chain falls are suitable for use in the following EX-classification:
EX II 2G Ex h IIB T4 Gb
or
EX II 2D Ex h IIIA T135°C Db or lower classification.
Hoists of 10 t capacity, 2 chain falls and up are only suitable for use only in the following
EX-classification:
EX II 2G Ex h IIB T3 Gb
or
EX II 2D Ex h IIIA T200°C Db or lower classification.
6
Installation
The assembly and installation depends on the local environment. The hoist must be suspended in a way that
it can position itself freely.
6.1
Trolley
For assembly on a beam a travel limit must be placed at either end of the track.
This must be attached so that any elastic limitation buffer or the trolley wheels are driven against them in
their end position when moving.
Generally, additional lifting gear (e.g. fork lift, lifting platforms) will be required for the assembly. These must
take the weight of the devices securely.
6.2
Tools
7
Control
Only people that are familiar with the operation of the lifting devices and cranes may be entrusted with their
operation. They must be authorized by the employer for the operation of the equipment. The employer must
ensure that the operating instructions are available near the equipment and that they are accessible for the
operating personnel.
Lifting and Lowering by pulling the endless hand
chain.
Lifting - pull the chain fall at the right side
–
the hand chain wheel turns clockwise
Lowering - pull the chain fall at the lift side
–
the hand chain wheel turns anti-clockwise
Illustration4
NOTICE!
For double lifting mechanism
Operate both lifting mechanism, synchronous resp.evenly.
CAUTION!
Run in of chain into the chain container for hoist with double lifting mechanism
For a correct run in of chain into both chain containers, the lowering operation must be carried out, without
load, at certain intervals, until both chain container are empty.
For motorized devices with operating limit switches "lowering"
Lower until the operating limit switch is released.
Non-observance can lead to device damages!
WARNING!
The hoist must always hang centrally under the beam or under its suspension point.