Betriebsanleitung
TGT, 26.06.2017
Technik
Seite 45 von 52
©Copyright by Habegger Maschinenfabrik AG
Version 03 / 26.06.2017
6
Faults
Faults
possible cause
Measure
Shear off the overload protection
Rope force too high
Reduce the load or use rope pulleys
Replace shearing pin *
Rope jams in device
Rope damaged or kinked, jammed at the
clamping jaws (bird-caging)
Incorrect rope used
Rope discharge jammed, rope run
against anchor bolt
Replace rope or
send the device to Habegger or an au-
thorized repair shop for repair
Use original Habegger rope. Ø according
to type plate
Clear the rope discharge
Rope not being transported,
Rope just goes back and forth
Rope worn out or
incorrect rope diameter used
Replace rope or
use original Habegger rope
Functional fault
Device dirty,
Foreign object inside
Take device apart (casing), clean, lubri-
cate
Casing bent or broken
Device was unable to adjust freely in the
direction of the tension.
Send the device to Habegger or an au-
thorized workshop for repair.
Anchor bolts or casing bent
Anchoring bolts not properly inserted or
not properly secured
Send the device to Habegger or an au-
thorized workshop for repair.
Load hook bent open
Incorrect load
Replace load hook
Icied
Cold
Defrost with hot air blower
* Replace shearing pin
If necessary, remove some of the load until the shearing bolt is outside the
casing, Image 9. Unlock and pull off the lever pipe by turning it.
Hit broken pieces of the pin out of the bore using a punch and hammer.
Remove the reserve pin from the clamping jaw opening lever (HIT 6/10) or
handle (HIT 16/32).
Line up the bores on the lever pieces and hammer in the new shearing pin.
Danger! Only use original Habegger brass shearing pins.
Stronger shearing pins can result in the pulley device overloading and breaking.
9