TECHNICAL DATA. 

Model 

4403405 

4403415 

Nominal power 

300W 

600W 

Peak power 

600W 

1200W 

Signal 

Pure Sine Wave 

Pure Sine Wave 

Nominal input voltage 

12V DC (10V-16V) 

12V DC (10V-16V) 

Nominal output voltage 

230  +/-10% V AC 

230  +/-10% V AC 

Frequency 

50+/-1 Hz 

50+/-1 Hz 

Stand-by power 

<0.45A 

<0.55A 

Efficiency 

>85% 

>85% 

Fan cooling 

yes 

yes 

Overheat protection 

75°C = shut-off 

(under 75°C 

=recovery) 

75°C = shut-off 

(under 75°C 

=recovery) 

Overload protection 

110-120% rated 

power= shut down 

110-120% rated 

power= shut down 

Low voltage protection 

alarm 

10.5 V +/- 0,5V 

10.5 V +/- 0,5V 

Low voltage protection 

cut off 

10V +/- 0,5V 

10V +/- 0,5V 

Over voltage protection 

cut off 

16 +/- 0,5V 

16 +/- 0,5V 

Reverse polarity 

protection 

yes / MOSFET 

yes / MOSFET 

Short circuit protection 

Yes / MOSFET 

 

Yes / Fuse 

DC 

 2x45 A  

 

Section / length of 

cables 

6mm

2

 / 60cm x 2 

10mm

2

 / 60cm x 2 

Connector on cables 

Ring Terminal 

M8+M10 

Ring Terminal 

M8+M10 

USB output 

5V  2.1A 

5V  2.1A 

 

Summary of Contents for 36191280

Page 1: ...IONS 5 3 1 REMOTE CONTROL Art 4403445 6 4 FITTING THE INVERTER 7 4 1 MOUNTING INSTRUCTIONS 7 4 2 MOUNTING THE INVERTER 8 5 CONNECTING THE INVERTER 8 5 1 GENERAL INSTRUCTIONS 8 5 2 WIRING DIAGRAM 9 5 3...

Page 2: ...fied workers who are familiar with the risks involved and the relevant regulations People including children whose physical sensory or mental capacities or whose lack of experience or knowledge preven...

Page 3: ...www haba nl info haba nl 3 USER MANUAL PURE SINE WAVE INVERTER 300W 600W 2 SCOPE OF DELIVERY The set include 1 Pure sine wave inverter 2 Earth cable 3 Battery cables 1 2 3...

Page 4: ...tage shutdown the inverter shuts itself off when the voltage sinks the cut off value It restarts automatically once the voltage rises to the normal values Exceed temperature shutdown the inverter shut...

Page 5: ...ROL ELEMENTS AND CONNECTIONS The inverter has the following connections and control elements on the left side No Description 1 230V AC output socket 2 Remote control socket 3 ON OFF switch 4 USB socke...

Page 6: ...C input negative pole 3 1 REMOTE CONTROL Art 4403445 NOT INCLUDED No Description 1 ON OFF switch 2 Battery capacity 5 levels 20 40 60 80 100 3 Load level 5 levels 20 40 60 80 100 4 ON OFF indication L...

Page 7: ...n a place that is protected from moisture The inverter may not be installed in the presence of flammable materials The inverter may not be installed in a dusty environment The place of installation mu...

Page 8: ...sis or earth Never use the inverter on vehicles where the positive terminal of the battery is connected to the chassis When setting up a socket distribution circuit mains setup comply with the applica...

Page 9: ...al and fasten it with the bolt d Connect the negative cable to the black negative terminal fig 3 e Lay the positive cable from the inverter to the positive terminal of the vehicle battery and connect...

Page 10: ...low voltage protection When DC input voltage is below 10 5 0 5 V DC buzzer sounds 2 times which indicates DC power supply voltage is decreasing and batteries need to be charged When input voltage reac...

Page 11: ...n the inner temperature exceed the 75 degrees buzzer sounds 5 times and red light turn on AC output will automatically shut off The inverter will on automatically once the temperature returns to the n...

Page 12: ...g yes yes Overheat protection 75 C shut off under 75 C recovery 75 C shut off under 75 C recovery Overload protection 110 120 rated power shut down 110 120 rated power shut down Low voltage protection...