background image

LAST UPDATED: 11/28/2018

Servo Amplifier - PCB Auxiliary (AUX) Load - Replacement

AD0263

Applies to machines built from: January, 1996

Introduction

1. Servo Amplifier
2. Smart Servo Amplifier
3. Smart Servo Amplifier with AUX Load

Do this procedure to install the AUX load [3]

when you install a Smart Servo Amplifier [2]. The

replacement amplifier must have the same amp

rating as the servo amplifier [1] that you remove.

You must install the AUX load [3] on the

replacement Smart Servo Amplifier [2] if you have

these two conditions:

• The machine has only two servo

amplifiers [1].

• You must replace only one of the servo

amplifiers [1] with a Smart Servo
Amplifier [2].

Note:

In other words, if after the installation

the machine has only one servo amplifier [1], the

replacement Smart Servo Amplifier must have

the AUX load [3].

Document Applies to these Parts

• 93-32-4995 PCB, AUXILIARY LOAD

SMART AMP

Servo Amplifier - PCB Auxiliary (AUX) Load - Replacement - AD0263

Page 1 of 2 pages