8
7.3.2.4. Setting TARGET room temperature (required room temperature)
■
∓
28°C
23°C
off
↱
+ -
OK
10:34
Procedure:
The “TARGET room temperature” is set with the
“Plus”
or
“Minus”
buttons.
The set value is saved by pressing the
“OK”
button.
The “TARGET room temperature” can be changed at any time as often as you want during operation with the
“Plus”
or
“Minus”
buttons.
Prerequisite: The welcome page must be shown on the display.
7.3.2.5. Starting the pellet stove - operating mode ON
10:34
■
∓
26°C
23°C
start zone 1
off
menu
Procedure:
On the standard screen, press the
“On/Off”
button to get the stove started.
Start Zone 1
now appears under
“Operating status”
and the start process begins.
By pressing the
“On/Off”
button again, the stove is switched back off.
OFF
then appears under
“Operating status”
.
The stove performs the ENTIRE start phase, however, until it reaches the necessary flame temperature and only then
switches to the cooling operating status and then OFF.
During the first use, odours may build up for a short time. Please ensure that there is adequate ventilation in
the installation room during this time and avoid inhaling directly!
General:
If the start phase could not be successfully completed i.e. no flame generation or the required temperature could not
be reached at the flue gas thermosensor, then a safety shutdown is initiated and an error message generated (“Error
2 – Date and time”). Before starting again, empty the burner and replace it.
8. Additional operator console functions
8.1. Backlighting
The backlighting of the display is switched off 5 minutes after the operator console was last operated and switches to
energy saving mode.
The backlighting is switched on by pressing on button. The function buttons are only active once the backlighting has
been activated. The backlighting is also activated by an error message being triggered.