![HAAS + SOHN Catania Installation And Operating Instructions Manual Download Page 21](http://html1.mh-extra.com/html/haas-sohn/catania/catania_installation-and-operating-instructions-manual_3121051021.webp)
21
11. Technical data
CATANIA 441.08
LUCCA 440.08
Heat output range:
1.8
– 8.2 kW
1.8
– 8.1 kW
Nominal heat output
8.0 kW
8.0 kW
Height:
1082 mm
1082 mm
Width:
795 mm
795 mm
Depth:
434 mm
434 mm
Weight:
142kg / 155kg
141 kg
Diameter of flue elbow:
80 mm
80 mm
Flue gas temperature
175 °C
175 °C
Minimum supply pressure:
6 Pa
6 Pa
Flue gas flow rate in g/s
-/5,6
-/5,6
CO
level in flue gas (%) (min./max.)
0,01
0,01
Efficiency:
92,2%
92,2%
CO level in flue gas:
87,5/125 mg/m³
87,5/125 mg/m³
NO
x
level in flue gas:
- /146 mg/m³
- /146 mg/m³
OGC level in flue gas:
5,8/3,1 mg/m³
5,8/3,1 mg/m³
Proportion of dust in flue gas:
-/6 mg/ m³
-/6 mg/ m³
Contents of storage container (pellet tank):
ca.32 kg
ca.32 kg
Duration of burn with one charge (min./max.):
ca. 25 h / 50 h
ca. 25 h / 50 h
Permitted fuel: Low-dust wood pellets to Ö-Norm
(Eco-standard) M 7135, DIN 51731, EN 14961-2
Diameter: 6 mm,
Length: max. 30 mm
Diameter: 6 mm,
Length: max. 30 mm
Room heating capacity to Ö-Norm M 7521:
max. 230 m
3
max. 230 m
3
Room heating cap’y to DIN 18893, constant heating:
250m
3
/145m
3
/98m
3
250m
3
/145m
3
/98m
3
Room heating cap’y to DIN 18893, timed heating:
165m
3
/95m
3
/65m
3
165m
3
/95m
3
/65m
3
Electricity supply:
230 V (50 Hz)
230 V (50 Hz)
Electricity supply input (min./max.)
in normal operation:
Electric ignition (for max. 15 minutes on ignition):
30 to 50 W
400 W
30 to 50 W
400 W
Electronics fuses: (F3)
T 0.315 A, 250 V
T 0.315 A, 250 V
Fuses for the ignition, screw conveyor motor, induced
draught, (F1,) (F2 reserve)
T 3,12 A, 250 V
T 3,12 A, 250 V
Figure 21:
Dimensions of Catania 441.08 + Lucca 440.08