2 | Information for Safety

Haag-Streit AG

6

1500 4000089 02010_web

2 Information for Safety

Residual Risks

The equipment from Haag-Streit has been designed and produced according to state of the art
standards and best practices at the time of manufacture. However, some residual risks remain and
are indicated on the equipment and in the form of safety messages (WARNING, CAUTION, NO-
TICE) in this document.

Explanation of Warnings

DANGER

Will lead to serious injury or death.

Follow the instructions to avoid a hazard.

WARNING

May lead to serious injury or death.

Follow the instructions to avoid a hazard.

CAUTION

May lead to light or moderately serious injuries.

Follow the instructions to avoid a hazard.

NOTICE

May lead to material damage and / or operating error.

Follow the instructions to avoid a hazard.

2.1 General Warnings

WARNING

Risk of life threatening electrical shock or uncontrolled system behavior!

The use of accessories, transformers and cables other than those specified (with the exceptions of
the transformers and cables supplied by the manufacturer as spare parts for internal components)
may increase electromagnetic emissions or reduce the system´s immunity to interference.

a) Only use approved accessories and spare parts.

b) Do not exceed the maximum load capacity of the carrier unit.

Summary of Contents for C.MOR HD

Page 1: ...Surgical Microscope Cameras C MOR HD C MOR HD Instructions for Use...

Page 2: ...nd Disinfection 18 6 2 1 Cleaning 18 6 2 2 Disinfection 20 6 2 3 Visual Guide for Cleaning and Disinfection 21 7 Operation of C MOR HD and C MOR HD 22 7 1 Symbols for Control Elements 22 7 2 Switch th...

Page 3: ...1500 4000089 02010_web iii 9 1 General 35 9 2 Maintenance Intervals 35 10 Disposable Materials and Spare Parts 36 11 Technical Data 37 12 Disposal 39 13 Appendix 40 13 1 Specifications on Electromagne...

Page 4: ...e from the respective components type plates You will find the contact details for your local sales representative in the notes pages of these in structions A current list of local sales representativ...

Page 5: ...Haag Streit AG Manufacturer s Details and Contact Information 1 1500 4000089 02010_web 5 Item Name 12 Product Name...

Page 6: ...or death Follow the instructions to avoid a hazard CAUTION May lead to light or moderately serious injuries Follow the instructions to avoid a hazard NOTICE May lead to material damage and or operati...

Page 7: ...of limited treatment options If defects are not detected the surgical microscope system may not offer all functions during sur gery a Before each use make sure that all electrical and mechanical conne...

Page 8: ...tate in which the user and or the patient is established First Installation and Commissioning The first installation and commissioning of the medical device must be done in accordance with the instruc...

Page 9: ...from third party suppliers have to be installed After maintenance or technical modifications the device must be readjusted following the service manual of the surgical microscope system In case of te...

Page 10: ...5 2 1 For connecting the power supply unit to the CCU 3 Power Supply Unit Supplies the CCU with power 4 IEC Socket C13 For connecting the power supply unit to the mains power socket 5 M23 Round Socket...

Page 11: ...ead Reference number REF serial number SN Health In dustry Bar Code HIBC of the camera head 2 CCU Connection For connecting the camera head to the camera control unit CCU 3 C Mount Connection For conn...

Page 12: ...tting the camera functions see Symbols for Control Elements 22 2 Menu Navigation Controls Buttons for selecting menu items and determining settings see Symbols for Control Elements 22 3 Button FUNCTIO...

Page 13: ...camera cable 6 IRIS For connecting an automatic aperture lens Not intended for use with the surgical microscope system 7 Power For connecting the power supply unit 8 SYNC Only for the 3D view functio...

Page 14: ...he camera head via camera cable 6 Power For connecting the power supply unit 7 SYNC Output for synchronizing when using two sets of cameras and CCUs Sends synchronization signals to the slave CCU 8 GE...

Page 15: ...rea can injure the patient a Ensure careful attachment of accessories 5 1 Connect the Camera Head For attaching the camera head a camera attachment with C mount adapter must be installed to the micros...

Page 16: ...the CCU onto the tray of the carrier unit 2 Connect the monitor to the CCU For using the VBS signal analog SD quality connect a BNC cable to the VBS output socket For using the S Video signal analog S...

Page 17: ...r supply unit into the mains power socket 5 3 Check the Image Alignment 1 Make sure that the orientation of the camera image matches the orientation of the micro scope s image The left and right sides...

Page 18: ...provided by the manufacturer of the disinfectant regarding recommended concentration and contact time After all appropriate items are cleaned disinfected or sterilized they should be inspected 1 Chec...

Page 19: ...t Let disinfectant dry out in air External surfaces Materials required Disposable gloves Cloth Damp cloth single use tissues or wipes cotton or mi crofiber cloth Cleaning agent glutaraldehyde based or...

Page 20: ...to surfaces 3 Use slightly soaked wipes with a sufficient amount of disinfectant 4 Let disinfected surfaces dry out in air 5 Be aware of the exposure time with the disinfectant 6 Be aware of the appli...

Page 21: ...ning and Disinfection Color Note Green Parts that are intended for cleaning and disinfection Black Parts that are intended to be touched by the user They must be cleaned and disinfected before and aft...

Page 22: ...on on HD MIOS or the external monitor works b In case of poor image quality reset the CCU to the default settings see Menu Settings 24 7 1 Symbols for Control Elements Button Function Switch the CCU o...

Page 23: ...enu This chapter only shows the most frequently required menu settings that can be used to improve the camera image under a wide range of environmental conditions Different types of surgery require di...

Page 24: ...ame function as hue adjustment via the button PAINT AE See Adjust Hue and Automatic Exposure PAINT AE 32 Gain Offset Blue 0 Adjusts the blue level Same function as hue adjustment via the button PAINT...

Page 25: ...Gain Control is set to AUTO Area Select NARROW Adjusts the extent of the measuring area for the automatic sensitivity settings based on the image that is displayed on the mon itor see Adjust Automati...

Page 26: ...3D Support SLAVE Sets the function of the CCU when 3D support is used Picture Setting DNR ON Activates the noise reduction DNR Level 8 Adjusts the noise reduction strength In creasing the value reduc...

Page 27: ...cene files Only for C MOR HD 7 3 2 Show or Hide Setup Menu 1 Make sure that an external monitor is connected to the CCU see Installation to the Surgical Microscope 15 2 Press the button MENU on the fr...

Page 28: ...at to the desired value 59 94 Hz The VBS signal outputs the NTSC format with a frame rate of 59 94 frames per second 50 Hz The VBS signal outputs the PAL format with a frame rate of 50 frames per seco...

Page 29: ...continuously and thereby white balance is set automatically This function is recom mended when lighting conditions change frequently 6 Confirm the entry by pressing the button FUNCTION SET on the fro...

Page 30: ...To change settings in the setup menu the menu lock must be deactivated 1 Open the Setup Menu 2 Select the menu item Miscellaneous 3 Set the value of the menu item Menu Lock to OFF The red lock mark in...

Page 31: ...item Menu Lock to ON 7 4 Perform Automatic White Balance AWB Whenever the lighting conditions change the white balance should be performed Otherwise the color reproduction of the camera image will be...

Page 32: ...temporary and will be reset if the CCU is switched off 1 Press the button PAINT AE on the front panel of the CCU to activate the hue adjustment The button PAINT AE lights up green and the hue adjustme...

Page 33: ...lor bar test pat tern If the button BARS lights up green the color bar test pattern is shown If the button BARS is not lit the color bar test pattern is hidden 7 8 Create Freeze Images FREEZE REC C MO...

Page 34: ...vice NOTICE Resettable error reoccurs twice or more The error may be due to a systematic fault in the medical device and must be attended by Haag Streit Please contact your local representative or Haa...

Page 35: ...ot described in these instructions must be conducted by authorized service technicians Maintenance tasks which can be conducted by the user are described in the following table User Maintenance Interv...

Page 36: ...e manufacturer as spare parts for internal components may increase electromagnetic emissions or reduce the system s immunity to interference a Only use approved accessories and spare parts b Do not ex...

Page 37: ...ance class I equipment EMC IEC 60 601 1 2 UMDNS 12 539 GMDN 12539 Degree of protection by enclosure IP Code IP20 Technical Data C MOR HD C MOR HD REF 4000011 4000012 Mechanical data Dimensions CCU Hei...

Page 38: ...resolution 900 TV lines 1000 TV lines Connections VBS PAL NTSC PAL NTSC Y C S Video S Video RS 232C not used not used FOOT SW not used not used Camera Connection of the camera head Connection of the c...

Page 39: ...European Union the surgical microscope system and its components are subject to EU Directive on Waste of Electrical and Electronic Equipment and may not be disposed together with waste from private ho...

Page 40: ...0 MHz 9 V m 704 MHz 787 MHz 28 V m 800 MHz 960 MHz 28 V m 1 7 GHz 1 99 GHz 28 V m 2 4 GHz 2 57 GHz 9 V m 5 1 GHz 5 8 GHz Electrical fast transient disturb ance bursts IEC 61000 4 4 For signal lines 1...

Page 41: ...HD SDI The HD SDI is a Serial Digital Interface primar ily for the transmission of uncompressed and un encrypted High Definition video data via coaxial cable HIBC HIBC is the abbreviation of the term...

Page 42: ...of the video picture signal V the blank ing signal B and the synchronization signal S The VBS signal is an analog video signal This transmission technique is also called composite video Y C Y C stands...

Page 43: ...Haag Streit AG 1500 4000089 02010_web 43...

Page 44: ...HS Art No 1500 4000089 02010_web 1 Edition 2024 02 Haag Streit AG Gartenstadtstrasse 10 3098 Koeniz Switzerland Phone 41 31 978 01 11 mail info haag streit com web www haag streit com...

Reviews: