Some NVMe drives might fail to be identified when
multiple NVMe drives are installed after OS
installation
Symptom
Some NVMe drives might fail to be identified when multiple NVMe drives are installed after OS
installation.
Solution
To resolve the issue:
1.
Install a next NVMe drive a minimum of 20 seconds after one NVMe drive is installed.
2.
If the issue persists, contact H3C Support.
Failed to install CASE0306 on an NVMe SSD
drive
Do not install CAS E0306 on an NVMe SSD drive.
The system cannot be restored after the server is
powered down unexpectedly
Symptom
The system cannot be restored after the server is powered down unexpectedly and the file system is
damaged.
Solution
CAUTION:
Forcibly powering down the server might damage your applications or data. Be cautious to perform
this operation based on your operating system.
To resolve the issue:
1.
Restart the system, select
rescue mode
on the GRUB page, execute the
xfs_repair –L
/dev/sdx
command to repair the damaged partition, and then restart the system.
2.
If the file system cannot be repaired, re-install the system.
3.
If the issue persists, contact H3C Support.