![H3C UniServer R4700 G6 Technology White Paper Download Page 20](http://html1.mh-extra.com/html/h3c/uniserver-r4700-g6/uniserver-r4700-g6_technology-white-paper_4421878020.webp)
19
(1) SlimSAS connector A1/A2 (PCIe4.0 x8)(NVME-A1/A2)
(2) x4 Mini-SAS-HD connector (SAS PORT)
•
x8
: Bus bandwidth.
Rear 2SFF UniBay drive backplane
The HDDCage-2UniBay-R-1U-G6 drive backplane can be installed at the server front to support
two 3.5-inch SAS/SATA/NVMe drives.
Figure 21 2SFF UniBay drive backplane
(1) SlimSAS connector A1/A2 (PCIe4.0 x8)(NVME-A1/A2)
(2) x4 Mini-SAS-HD connector (SAS PORT)
(3) AUX connector (AUX)
(4) Power connector (PWR)
PCIe4.0 x8 description:
•
PCIe4.0
: Fourth-generation signal speed.
•
x8
: Bus bandwidth.
Riser cards
The R4700 G6 supports the following riser card models:
•
RC-1HHHL-R3-1U-SW-G6
•
RC-1HHHL-R4-1U-X16-G5
•
RC-2FHFL-1U-SW-G6
RC-1HHHL-R3-1U-SW-G6
Item
Specifications
PCIe riser connector
Connector 3
PCIe slots
Slot 3: PCIe5.0 ×16 (16, 8, 4, 2, 1) for processor 2
NOTE:
The numbers in parentheses represent supported link widths.
Form factors of PCIe modules
HHHL
Maximum power supplied per PCIe slot 75 W