2-13
Figure 2-10 Internal connections between external interfaces of straight-through module and
full-width single-height blade server (supports up to 6 Mezz NICs)
3. Correspondence between external interfaces of straight-through module and full-width
single-height blade server (supports up to 3 Mezz NICs)
shows the 16 FC interfaces on the straight-through module panel, which are numbered
shows the slots for the 8 full-width single-height blade servers installed in
the front slots of the blade server chassis. They are numbered 1, 3, 5, 7, 9, 11, 13, and 15.
When the full-width single-height blade server that supports up to 3 Mezz NICs is installed in the
front slots of the chassis:
•
As shown in
, the straight-through modules connected to slots 1, 3, 4, and 6 are
connected to blade servers through odd-number interfaces. That is, port 1 is connected to
blade server 1, and users can access blade server 1 through port 1; port 3 is connected to
blade server 3, and users can access blade server 3 through port 3; and so on.
Note
•
For the correspondence between the straight-through modules connected to different slots and the
blade server Mezz NICs, see
2.5.1 Connections Between Straight-Through Modules and Mezz
•
For details about blade server Mezz NIC ports that are connected to straight-through modules,
contact Technical Support.
ICM
Front
Port 1
Port 2
Port 3
……
Port 4
Port 13
Port 14
Port 15
Port 16
Blade1
Blade3
Blade13
Blade15
……