Replace the blade server.
•
When you replace a component, examine the slot and connector for damages. Make sure the
pins are not damaged (bent for example) and do not contain any foreign objects.
•
You might also remove other components. For the removed components to be reinstalled
correctly, record their positions and connections before removal, for example, taking pictures of
cable connection and drive installation positions, or labeling cables.
•
For the specific installation guidelines of riser card and PCIe card, see "
."
Removing the riser card and PCIe card
1.
Remove the chassis cover. Press the chassis cover unlock button, slide toward the rear of the
blade server, and then lift the cover up.
a.
Press the chassis cover unlock button and slide toward the rear of the server.
b.
Lift the chassis cover up to remove it from the server.
2.
Remove the riser card with PCIe card. Lift the riser card up to remove it from the server chassis
.
3.
Remove the PCIe card from the riser card. Press and open the fixing buckle on the riser card,
and then lift the PCIe card up to remove it from the riser card.
Installing the riser card and PCIe card
1.
Install the PCIe card to the riser card.
a.
Open the fixing buckle on the riser card. Press the locking button on the fixing buckle and
open the fixing buckle.
b.
(Optional) Remove the PCIe card filler panel. Lift the filler panel up and remove it from the
riser card.
c.
InstallIng the PCIe card to riser card connector Insert the PCIe card along the PCIe
connector on the riser card, and then close the PCIe card fixing buckle.
2.
Install the riser card with the PCIe card in the blade server.
a.
(Optional) Remove the filler panel. Lift the filler panel up.
b.
Install the riser card with the PCIe card in the blade server. Insert the riser card downward
as aligning the two mushroom-shaped heads on the riser card with the two notches on the
blade server.
3.
Install the chassis cover. Place the chassis cover horizontally downward as aligning the
mushroom-shaped head on the chassis cover with the groove on the chassis, and slide the
chassis cover toward the front of the server until it is locked.
4.
Install the blade server.
5.
Power on the blade server. For the specific steps, see "
."