H3C SR6608/6604 Routers Installation Manual
Chapter 1 Router Overview
1-38
(1) Captive screw
(2) Power input terminals
(3) Power switch
(4) Power LED
(5) Power module handle
Figure 1-22
DC power module
1.4.4 Port Lightning Arrester (Optional)
Before connecting an outdoor Ethernet cable to an Ethernet port, you can install a port
lightning arrester to protect the router against lightning strokes. The following port
lightning arrester can be installed on the device. The specifications for the port lightning
arrester are as follows:
Port protective unit–single port, maximum discharge current (8/20
μ
s waveform): 5 kA,
output voltage (10/700
μ
s waveform): core-core < 40 V, core-ground < 600 V.
Note:
For the installation of the port lightning arrester, refer to section 5.6 “Installing a Port
Lightning Arrester (Optional)” in Chapter 5 “Installing the Router”.
1.4.5 Power Lightning Arrester (Optional)
Before connecting an outdoor AC power to the router, you need to install a lightning
protection busbar at the AC power input end and then connect the AC power cord to a
lightning protection busbar to protect the router against lightning strokes. In a heavy
lightning area, you are recommended to install a power lightning arrester.
The following power lightning arrester can be installed on the device. The specifications
for the power lightning arrester are as follows:
Maximum discharge current: 6500 A, protection voltage: 500 VAC to 220 VAC.