28
Default
Dispute guard is enabled.
Views
System view
Predefined user roles
network-admin
Usage guidelines
Dispute guard blocks a port to prevent loops when a unidirectional link is detected on the port by the
spanning tree feature.
In some VLAN networks, an uplink port on a downstream device is configured to deny packets from
the PVID. As a result, the downstream device cannot receive BPDUs of the PVID from the upstream
device. However, the upstream device can receive BPDUs from the downstream device. In this case,
dispute guard blocks the receiving port on the upstream device, which causes traffic interruption.
To ensure service continuity and prevent the link from being blocked, you can disable dispute guard
by using the
undo stp dispute-protection
command.
Examples
# Disable dispute guard.
<Sysname> system-view
[Sysname] undo stp dispute-protection
stp edged-port
Use
stp edged-port
to configure a port as an edge port.
Use
undo stp edged-port
to restore the default.
Syntax
stp edged-port
undo stp
edged-port
Default
All ports are non-edge ports.
Views
Layer 2 Ethernet interface view
Layer 2 aggregate interface view
Predefined user roles
network-admin
Usage guidelines
A port directly connecting to a user terminal rather than another device or a shared LAN segment can
be configured as an edge port. In case the network topology changes, an edge port does not cause
a temporary loop. You can enable the port to transit to the forwarding state rapidly by configuring it as
an edge port. As a best practice, configure ports that directly connect to user terminals as edge ports.
Typically, configuration BPDUs from other devices cannot reach an edge port, because the edge port
does not connect to any other device. When BPDU guard is disabled on a port configured as an edge
port, the port acts as a non-edge port if it receives configuration BPDUs.
On a port, the loop guard feature and the edge port setting are mutually exclusive.
Summary of Contents for SOHO IE4300
Page 285: ...i Contents Tcl commands 1 cli 1 tclquit 1 tclsh 2...
Page 288: ...i Contents Python commands 1 exit 1 python 1 python filename 2...
Page 291: ...i Contents Automatic configuration commands 1 autodeploy udisk enable 1...
Page 323: ...25 Sysname Ten GigabitEthernet1 0 51 undo shutdown Related commands irf port...
Page 465: ...ii stp vlan enable 55 vlan mapping modulo 55...
Page 602: ...12 Related commands display mvrp statistics...
Page 609: ...i Contents VLAN mapping commands 1 display vlan mapping 1 vlan mapping 2...
Page 678: ...9 Related commands reset pppoe relay statistics...
Page 846: ...i Contents Basic IP forwarding commands 1 display fib 1 ip forwarding table save 2...
Page 1770: ...i Contents Time range commands 1 display time range 1 time range 1...
Page 2026: ...34 Related commands display mac authentication...
Page 2028: ...ii...
Page 2143: ...i Contents User profile commands 1 display user profile 1 user profile 2...
Page 2308: ...61 ipsec transform set...
Page 2531: ...i Contents SAVI commands 1 ipv6 savi down delay 1 ipv6 savi log enable 1 ipv6 savi strict 2...
Page 2534: ...3 Sysname ipv6 savi strict Related commands ipv6 verify source...
Page 2791: ...14 Sysname track 1 Related commands delay display track...
Page 2939: ...9 sntp authentication keyid sntp reliable authentication keyid...
Page 2967: ...27 Related commands apply poe profile poe enable poe max power interface view poe priority...