1  Identifier 

The module identifier NSQM2GP24TSSC0 is in the upper right corner of the front panel. 

2  About the module 

The NSQM2GP24TSSC0 interface module provides twenty-four 1000BASE-X SFP fiber ports and 
four 10GBASE-R SFP+ fiber ports. By using this module with high-performance service modules, 
the device is capable of providing security for 100G networks. 

3  Specifications 

Figure 1 Front panel 

 

(1) 1000BASE-X SFP fiber port LEDs 

(2) 10GBASE-R SFP+ fiber port LEDs 

(3) 10GBASE-R SFP+ fiber ports 

(4) 1000BASE-X SFP fiber ports 

(5) Ejector lever 

(6) Captive screw 

 

 

IMPORTANT: 

Before installing the module, you must remove the protection cover from the module. 

 

Table 1 Module specifications 

Item Specification 

Dimensions (H × W × D) 

40.1 × 399.2 × 354.8 mm (1.58 × 15.72 × 13.97 in) 

SDRAM (DDR3) 

1 GB 

Power consumption 

27 W to 52 W 

Net weight 

2.85 kg (6.28 lb) 

Hot swapping 

Supported 

Ports 

 

24 × 1000BASE-X SFP fiber ports 

 

4 × 10GBASE-R SFP+ fiber ports 

Connector type 

LC 

Summary of Contents for SecPath NSQM2GP24TSSC0

Page 1: ...of providing security for 100G networks 3 Specifications Figure 1 Front panel 1 1000BASE X SFP fiber port LEDs 2 10GBASE R SFP fiber port LEDs 3 10GBASE R SFP fiber ports 4 1000BASE X SFP fiber ports 5 Ejector lever 6 Captive screw IMPORTANT Before installing the module you must remove the protection cover from the module Table 1 Module specifications Item Specification Dimensions H W D 40 1 399 2...

Page 2: ...0BASE X SFP fiber ports and 10GBASE R SFP fiber ports Module Central wavelength nm Connector type Cable specifications Maximum transmission distance SFP GE SX MM850 A 850 LC 50 125 µm MMF 550 m 0 34 miles 62 5 125 µm MMF 275 m 0 17 miles SFP GE LX SM1310 A 1310 LC 9 125 µm SMF 10 km 6 21 miles 50 125 µm MMF 550 m 1804 46 ft 62 5 125 µm MMF 550 m 1804 46 ft SFP GE LH40 SM1310 1310 LC 9 125 µm SMF 4...

Page 3: ...esent on the port Off No link is present on the port 5 Installing and removing the module CAUTION Wear a reliably grounded ESD wrist strap or ESD gloves when installing or removing the module Do not touch the components on the module 5 1 Installing the module 1 Face the front panel of the device Remove the filler panel from the target slot This example uses slot 2 2 Place the module on a flat surf...

Page 4: ... separate the module from the backplane and pull the module slowly out of the slot along the guide rails 3 Place the module on an anti static workbench or put it in an anti static bag with the component side facing up 4 If you are not to install a new module install a filler panel in the slot to prevent dust and ensure good ventilation in the device Copyright 2019 New H3C Technologies Co Ltd The i...

Reviews: