18
The firewall comes with the PWR1 slot empty and the PWR0 slot installed with a filler panel.
Figure2-12 Removing the filler panel from a firewall
3.
Orient the power supply with its handle at the right. Holding the handle of the module with one
hand and supporting the module bottom with the other, slide the power supply slowly into the
slot along the guide rails.
Figure2-13 Installing a power supply for a firewall
Installing an interface module
CAUTION:
•
Interface modules are not hot swappable.
•
To install two interface modules, use the upper interface module slots as a best practice. If you
have installed an interface module in a lower slot, you must press down the ejector levers of the
interface module while inserting it into an upper slot.
No interface modules are provided with the firewall. Purchase them as needed.
The installation procedure is the same for all interface modules.
To install an interface module:
1.
Use a screwdriver to remove the screws on the filler panel and then remove the filler panel.
Keep the filler panel for future use.