background image

Manual Version

:6PW103-20121130 

BOM:3123A13Q

 

H3C SecPath F5000-A5 NSQ1MPUA0 Card Manual  

 

Appearance 

Figure 1 Appearance of the NSQ1MPUA0 

 

 

 

Specifications 

The NSQ1MPUA0 works with other service cards to provide the firewall feature. In addition, the 

NSQ1MPUA0 is used to upgrade and maintain the firewall software.  
The NSQ1MPUA0 provides, from left to right on its front panel, one management Ethernet port, one HA 

port, one Console port, one AUX port, one external CF card slot, two USB interfaces, LEDs, and one 

Reset button. 

Summary of Contents for SecPath F5000-A5 NSQ1MPUA0

Page 1: ...he NSQ1MPUA0 works with other service cards to provide the firewall feature In addition the NSQ1MPUA0 is used to upgrade and maintain the firewall software The NSQ1MPUA0 provides from left to right on its front panel one management Ethernet port one HA port one Console port one AUX port one external CF card slot two USB interfaces LEDs and one Reset button ...

Page 2: ...ot 16 CF card LED CF 17 Run LED RUN 18 Active LED of the MPU ACT 19 Alarm LED ALM 20 Reset button RESET Table 1 NSQ1MPUA0 specifications Item Specification Flash 4 MB Memory type and size DDR2 SDRAM 2 memory slots 4 GB default two 2 GB memory chips Memory modules must be used in pairs with the same size NVRAM 256 KB Console port 1 9600 bps default to 115200 bps AUX port 1 9600 bps default to 11520...

Page 3: ... on the management Ethernet port ALM Red Off The system is operating properly with no alarms On A fault has occurred to the system or the available power is not enough In this state check the system log immediately Fast flashing 8 Hz A critical fault has occurred to the system In this state handle the fault immediately LINK Green Off No link is present on the HA port On A link is present on the HA...

Page 4: ...he MPU in position Figure 3 Insert the NSQ1MPUA0 4 Fasten the captive screws on the MPU with a Phillips screwdriver 5 The RUN LED green flashes fast at 8 Hz It flashes slowly at 1 Hz after the MPU application is loaded This means that the MPU is operating properly 3 2 Removing the NSQ1MPUA0 1 Face the front panel of the firewall 2 Loosen the captive screws with a Phillips screwdriver until all pre...

Page 5: ...ntation For card installation see the H3C SecPath F5000 A5 Firewall Installation Guide If the firewall software version does not match contact the vendor or the integrator for the right version Take the following steps to get the latest documentation from the H3C website at www h3c com Go to http www h3c com portal Technical_Documents or click Technical Support Documents Technical Documents on the...