13
2.
Enter interface view.
{
Enter Layer 2 aggregate interface view.
interface bridge-aggregation interface-number
{
Enter VXLAN tunnel interface view.
interface tunnel number
3.
Specify the interface as the IPP.
port drni intra-portal-port
port-id
Disabling configuration consistency check
About disabling configuration consistency check
To ensure that the DR system can operate correctly, DRNI by default performs configuration
consistency check when the DR system is set up.
Configuration consistency check might fail when you upgrade the DR member devices in a DR
system. To prevent the DR system from falsely shutting down DR interfaces, you can temporarily
disable configuration consistency check.
Restrictions and guidelines
Make sure the DR member devices use the same setting for configuration consistency check.
Procedure
1.
Enter system view.
system-view
2.
Disable configuration consistency check.
drni consistency-check disable
By default, configuration consistency check is enabled.
Enabling the short DRCP timeout timer on the IPP
or a DR interface
About the DRCP timeout timer
By default, the IPP or a DR interface uses the 90-second long DRCP timeout timer. To detect peer
interface down events more quickly, enable the 3-second short DRCP timeout timer on the interface.
Restrictions and guidelines
To avoid traffic interruption during an ISSU or DRNI process restart, disable the short DRCP timeout
timer before you perform an ISSU or DRNI process restart. For more information about ISSU, see
Fundamentals Configuration Guide
.
Procedure
1.
Enter system view.
system-view
2.
Enter interface view.
{
Enter Layer 2 aggregate interface view.
interface bridge-aggregation interface-number
{
Enter VXLAN tunnel interface view.
interface tunnel number