H3C S6805 Series Hardware Information Download Page 1

 

H3C S6805 Switch Series 

Hardware Information and Specifications 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Document version: 6W100-20220510 
 
Copyright © 2022 New H3C Technologies Co., Ltd. All rights reserved. 
No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of 
New H3C Technologies Co., Ltd. 
Except for the trademarks of New H3C Technologies Co., Ltd., any trademarks that may be mentioned in this document 
are the property of their respective owners. 
The information in this document is subject to change without notice

 

Summary of Contents for S6805 Series

Page 1: ...art of this manual may be reproduced or transmitted in any form or by any means without prior written consent of New H3C Technologies Co Ltd Except for the trademarks of New H3C Technologies Co Ltd an...

Page 2: ...er supplies 3 8 Fan trays 3 9 4 Ports and LEDs 4 11 Ports 4 11 Console port 4 11 Management Ethernet port 4 11 USB port 4 12 SFP port 4 12 QSFP28 port 4 14 1 10GBASE T autosensing Ethernet port 4 17 L...

Page 3: ...b 10 kg 22 05 lb Console port 1 mini USB console port 1 serial console port 1 mini USB console port 1 serial console port Management Ethernet port 1 10M 100M 1000MBASE T copper port 1 SFP port 1 10M 1...

Page 4: ...ts 95 W PSR450 12A PSR450 12A1 Single AC input 93 W Dual AC inputs 100 W PSR450 12AHD Single DC input 91 W Dual DC inputs 102 W PSR450 12D Single DC input 94 W Dual DC inputs 101 W Typical power consu...

Page 5: ...e level at 27 C 80 6 F 53 6 dB A 53 7 dB A Operating temperature 0 C to 45 C 32 F to 113 F Operating humidity 5 RH to 95 RH noncondensing Fire resistance compliance UL60950 1 EN60950 1 IEC60950 1 GB49...

Page 6: ...thernet port LED LINK ACT 15 Copper management Ethernet port 16 Fiber management Ethernet port LED LINK ACT The S6805 54HF switch has a serial label pull tab on the rear panel It provides the ESN and...

Page 7: ...ray 2 7 Fan tray 3 8 Fan tray 4 9 Fan tray 5 10 Power supply 1 11 Power supply 2 12 System status LED SYS 13 Serial label pull tab 14 Copper management Ethernet port LED LINK ACT 15 Copper management...

Page 8: ...tray slots empty You must install five fan trays of the same model for the switch In Figure2 5 five LSPM1FANSA fan trays are installed in the fan tray slots Figure2 6 Left side panel 1 Primary ground...

Page 9: ...S6805 54HF S6805 54HT Power supplies PSR250 12A 0231A6M0 Yes No PSR250 12A1 0231A8FP Yes No PSR450 12A 0231A6N9 Yes Yes PSR450 12A1 0231A6NC Yes Yes PSR450 12AHD 0231A6NA Yes Yes PSR450 12D 0231A6NB Y...

Page 10: ...90 VAC 47 to 63 Hz Max output power 450 W High voltage DC input Rated input voltage range 240 VDC Max input voltage range 180 to 320 VDC Max output power 450 W For more information about the power sup...

Page 11: ...ide LSPM1FANSB LSPM1FANSB SN Dimensions 41 40 105 mm 1 61 1 57 4 13 in including the handle Fan number 1 Fan speed 20000 R P M Max airflow 20 CFM 0 57 m 3 min Airflow direction From the port side to t...

Page 12: ...ission baud rate 9600 bps default to 115200 bps Services Provides connection to an ASCII terminal Provides connection to the serial port of a local or remote through a pair of modems PC running termin...

Page 13: ...compliant USB2 0 port that can upload and download data at a rate up to 480 Mbps You can use this USB port to access the file system on the flash file system of the switch for example to upload or dow...

Page 14: ...Multi mode 62 5 125 200 275 m 902 23 ft 160 220 m 721 78 ft SFP GE LX SM 1310 A 1310 LC Single mode 9 125 N A 10 km 6 21 miles Multi mode 50 125 500 or 400 550 m 1804 46 ft Multi mode 62 5 125 500 550...

Page 15: ...94 ft LSWM3STK 3 m 9 84 ft LSTM1STK 5 m 16 40 ft Table4 8 SFP fiber cables available for the SFP ports SFP fiber cable Max transmission distance Data rate SFP XG D AOC 7M 7 m 22 97 ft 10 31 Gbps SFP...

Page 16: ...984 25 ft QSFP 100G S WDM4 MM850 Four lanes 850 880 910 940 LC Multi mode 50 125 2000 75 m 246 06 ft 4700 100 m 328 08 ft QSFP 100G PS M4 SM1310 1295 to 1325 MPO APC polished 12 fiber Single mode 9 1...

Page 17: ...s QSFP transceiver module Central wavelength nm Connector Fiber type and diameter m Modal bandwidth MHz km Max transmission distance QSFP 40G SR 4 MM850 850 MPO PC polished 12 fiber Multi mode 50 125...

Page 18: ...m 9 84 ft 40 Gbps QSFP 40G D AOC 7M 7 m 22 97 ft QSFP 40G D AOC 10M 10 m 32 81 ft QSFP 40G D AOC 20M 20 m 65 62 ft Table4 16 40G QSFP to 4 10G SFP copper cables available for the QSFP28 ports QSFP fi...

Page 19: ...frame connect port 1 on the device to port 1 on the distribution frame port 2 on the device to port 3 on the distribution frame and port 3 on the device to port 5 on the distribution frame If the dev...

Page 20: ...green The port is sending or receiving data at 100 Gbps Steady yellow A transceiver module or cable has been correctly installed The port has a link and is operating at 40 Gbps Flashing yellow 3 Hz T...

Page 21: ...K ACT Off No link is present Steady green The port is operating at 1000 Mbps and a link is present Flashing green The port is receiving or sending data at 1000 Mbps Steady yellow The port is operating...

Page 22: ...nstallation site for the switch Table5 1 Cooling system for the switch Available fan trays Airflow direction LSPM1FANSA LSPM1FANSA SN From the power supply side to the port side LSPM1FANSB LSPM1FANSB...

Reviews: