H3C S6800-54QF & S6800-54HF Switches Installation Quick Start-6W105
H3C S6800-54QF & S6800-54HF
交换机 快速安装指南
-6W105
Installation accessories
安装附件介绍
No installation tools are provided with the switch. Prepare them yourself as required.
交换机不随机提供安装工具,请用户根据实际安装需求自己准备安装工具。
Phillips screwdriver
十字螺丝刀
ESD wrist strap
防静电腕带
Marker
记号笔
Tool list
工具参考
Mounting the switch in a rack
安装交换机到机柜
Grounding cable
地线
Attach the mounting brackets and chassis rails to the switch
安装挂耳和滑道导轨到交换机
Grounding screw
接地螺钉
Wear an ESD wrist strap, and make sure the strap makes good skin contact and is reliably grounded.
操作者需佩戴防静电腕带,确保防静电腕带与皮肤良好接触,并确认防静电腕带已经良好接地。
!
1
2
Rack-mount rail kit B
(with super-short slide rails) (optional)
超短滑道和导轨(选配)
Rack-mount rail kit C (optional)
滑道和导轨(选配)
Flathead screwdriver
一字螺丝刀
For an LS-6800-54QF-H3 switch, if the rack has a depth (distance between the front and rear rack
posts) in the range of 621 to 793 mm (24.45 to 31.22 in), use mounting brackets and rack-mount rail kit
A. If the rack has a depth in the range of 330 to 505 mm (12.99 to 19.88 in), use mounting
brackets and rack-mount rail kit B (narrow-spacing installation of chassis rails). If the rack has a
depth in the range of 438 to 632 mm (17.24 to 24.88 in), use mounting brackets and rack-mount
rail kit B (wide-spacing installation of chassis rails).
For the other switch models, if the rack has a depth in the range of 621 to 854 mm (24.45 to 33.62
in), use mounting brackets and rack-mount rail kit A. If the rack has a depth in the range of 401 to 634
mm (15.79 to 24.96 in), use mounting brackets and rack-mount rail kit C.
对于
LS-6800-54QF-H3
机型, 挂耳与长滑道和导轨配合安装适用于机柜前后方孔条间距范围为
621
~
793mm
。挂耳与超短滑道和导轨配合安装到机柜时,滑道导轨有正向安装和反向安装两种方式:导轨
正向安装适用于机柜前后方孔条间距范围为
330
~
505mm
;导轨反向安装适用于机柜前后方孔条间距
范围为
438
~
632mm
。
对于其他机型,挂耳与长滑道和导轨配合安装适用于机柜前后方孔条间距范围为
621
~
854mm
。挂耳
与滑道和导轨配合安装适用于机柜前后方孔条间距范围为
401
~
634mm
。
Rack-mount rail kit A
(with long slide rails)
长滑道和导轨
Install the mounting brackets near the port side or power module side of the switch as needed. Attach
the chassis rails to the switch based on the mounting bracket installation position and rack depth.
用户可以根据安装场景的需要,将挂耳安装在设备靠近端口侧或靠近电源侧,并根据机柜深度,在交换
机侧面板的对应位置安装滑道导轨。
1
Install the mounting brackets near the power
module side
挂耳安装到靠近电源侧
Attaching the mounting brackets and chassis rails of rack-mount rail kit A to the switch
挂耳与长滑道的导轨配合安装
Install the mounting brackets near the port side
挂耳安装到靠近端口侧
The mounting bracket and slide rail installation procedures are similar for the switches. The following
procedures use an LS-6800-54QF-H3 switch.
交换机各款机型安装挂耳、长滑道或滑道到交换机的方
式相似,此处以产品代码为
LS-6800-54QF-H3
的机型为例。
Use three screws to secure a mounting bracket at the port side. For the LS-6800-54QF-H3, use four
screws.
产品代码为
LS-6800-54QF-H3
的机型,挂耳安装在靠近端口侧时,使用四颗螺钉安装挂耳。
其它机型请使用三颗螺钉将挂耳安装在靠近端口侧。
Mounting brackets and M4 screw
前挂耳和
M4
螺钉
Type A
类型一
Type B
类型二
Cable tie
可拆卸式扎带
M6 screw and cage nut
(user supplied)
M6
螺钉和浮动螺母
(
用户自备
)
Filler module
假面板
Type A
类型一
Type B
类型二