181
Table 38
Command output
Field Description
transceiver diagnostic information
Digital diagnosis information of the transceiver in the
interface.
Current diagnostic parameters
Current diagnostic parameters.
Temp.(°C)
Digital diagnosis parameter-temperature, in °C, with the
precision to 1°C.
Voltage(V)
Digital diagnosis parameter-voltage, in V, with the
precision to 0.01 V.
Bias(mA)
Digital diagnosis parameter-bias current, in mA, with the
precision to 0.01 mA.
RX power(dBM)
Digital diagnosis parameter-RX power, in dBM, with the
precision to 0.01 dBM.
TX power(dBM)
Digital diagnosis parameter-TX power, in dBM, with the
precision to 0.01 dBM.
display transceiver manuinfo
Use
display transceiver manuinfo
to display the electronic label data for transceiver modules.
Syntax
display transceiver manuinfo
interface
[
interface-type interface-number
] [
|
{
begin
|
exclude
|
include
}
regular-expression
]
Views
Any view
Default command level
2: System level
Parameters
interface
[
interface-type interface-number
]: Displays the electronic label data for the transceiver module
in an interface. The
interface-type interface-number
argument specifies represents interface type and
interface number. If no interface is specified, this command displays the electronic label data for the
transceiver modules in all interfaces.
|
: Filters command output by specifying a regular expression. For more information about regular
expressions, see
Fundamentals Configuration Guide
.
begin
: Displays the first line that matches the specified regular expression and all lines that follow.
exclude
: Displays all lines that do not match the specified regular expression.
include
: Displays all lines that match the specified regular expression.
regular-expression
: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Usage guidelines
The
display transceiver manuinfo
command cannot display information for some transceiver modules.