136
To do…
Use the command…
Remarks
Perform a manual
version rollback
issu rollback slot
slot-number
Optional
By default, automatic rollback is performed to revert
to the previous version.
The
slot-number
argument provided in this
command must be the same as that specified in the
issu load
command.
NOTE:
During an ISSU upgrade process, if you modify the rollback timer after executing the
issu load
command,
the new rollback timer does not take effect for this ISSU process.
Displaying and maintaining ISSU
To do…
Use the command…
Remarks
Display information about the
rollback timer
display issu rollback-timer
[
|
{
begin
|
exclude
|
include
}
regular-expression
]
Available in any view
Display the ISSU state
display issu state
[
|
{
begin
|
exclude
|
include
}
regular-expression
]
Available in any view
Display version compatibility
information
display version comp-matrix
[
file
upgrading-filename
] [
|
{
begin
|
exclude
|
include
}
regular-expression
]
Available in any view