H3C S5170-EI & S5570S-EI Switch Series
Installation Guide
New H3C Technologies Co., Ltd. http://www.h3c.com Document version: 6W101-20221011
Page 1: ...H3C S5170 EI S5570S EI Switch Series Installation Guide New H3C Technologies Co Ltd http www h3c com Document version 6W101 20221011...
Page 2: ...espective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be accur...
Page 3: ...enclose syntax choices keywords or arguments that are optional x y Braces enclose a set of required syntax choices separated by vertical bars from which you select one x y Square brackets enclose a s...
Page 4: ...s a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Represents an access controller a unified wired WLAN module or the access controller engine on a u...
Page 5: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments...
Page 6: ...onnecting the power cord for a built in power supply 18 Connecting the power cord for a CA 70A12 or PSR75 12A power supply 19 Connecting the power cord for a PSR150 D1 or PSR560 56D power supply 20 Co...
Page 7: ...ii Removable power supply failure 1 Fan tray failure 2 Configuration terminal display issues 2 No display 2 Garbled display 2...
Page 8: ...LS 5570S 54S EI GL S5570S 28S HPWR EI LS 5570S 28S HPWR EI S5570S 28S HPWR EI A LS 5570S 28S HPWR EI A LS 5570S 28S HPWR EI A GL S5570S 54S PWR EI LS 5570S 54S PWR EI S5570S 54S PWR EI A LS 5570S 54S...
Page 9: ...e requirements listed in Table 2 Table 2 Checking list for the installation environment Item Requirements Ventilation and heat dissipation CAUTION To ensure correct operation of your device make sure...
Page 10: ...responding network interface Keep the signal cables far from power cords and lightning rod down conductors As a best practice route power cords indoors If an AC power cord is routed from outdoors conn...
Page 11: ...from pollution sources Do not smoke eat or drink in the equipment room Use double layer glass in windows and seal doors and windows with dust proof rubber strips Use screen doors and window screens f...
Page 12: ...site meets the installation requirements The switch can operate correctly in an A1 or A2 installation site Availability issues might occur if you install the switch in an A3 B1 B2 or C installation s...
Page 13: ...r distribution or power supply environment Table 7 Requirements for power distribution or power supply environment Item Requirements Preparation The power supply must be available before you install t...
Page 14: ...Installation accessories Code Description Quantity Applicable device models N A Front mounting kit including a pair of front mounting brackets and eight M4 screws 1 pair provided All models N A Rear...
Page 15: ...ns The AC power cord in this table is a standard AC power cord in China 1 provided for the switch with a built in power supply 1 provided with removable power supplies All models N A DC power cord 1 p...
Page 16: ...ls N A Releasable cable tie 1 provided with the PSR180 56A PSR360 56A PSR720 56A PSR1110 56A PSR600 54A B PSR920 54A B and PSR1600 54A B power supplies S5570S 28S HPWR EI S5570S 54S PWR EI S5570S 28S...
Page 17: ...sion Otherwise H3C shall not be liable for any consequence Figure 1 Hardware installation flow Start Install the switch Ground the switch Connect the power cords Verify the installation Turn on circui...
Page 18: ...ing front mounting brackets S5570S 28S HP WR EI S5570S 54S PW R EI S5570S 30MS U PWR EI Using front and rear mounting brackets Select an installation position for the front mounting brackets as requir...
Page 19: ...as one mounting position near the network ports and the other mounting position near the power supplies for the front mounting brackets Select one position as needed To attach the front mounting brack...
Page 20: ...the front mounting brackets have been securely attached to the switch chassis See Attaching the front mounting brackets to the switch 3 Attach cage nuts to the front rack posts 4 One person supports...
Page 21: ...re 6 Mounting the switch in the rack port side mounting position for the front mounting brackets Figure 7 Mounting the switch in the rack power supply side mounting position for the front mounting bra...
Page 22: ...h the mounting bracket to the chassis As a best practice use a torque of 12 kgf cm 1 18 Nm to fasten the M4 screws 4 Repeat the preceding two steps to attach the other mounting bracket to the chassis...
Page 23: ...with the wide flange inside the rack Figure 10 Attaching the rear mounting brackets to the rack with the wide flange outside the rack Mounting the switch in the rack 1 Wear an ESD wrist strap Make sur...
Page 24: ...the other and pushes the chassis into the rack gently Make sure the shoulder screws rest firmly on the upper edge of the rear mounting brackets See Figure 11 and Figure 12 5 The other person attaches...
Page 25: ...bottom with dry cloth 3 Attach the rubber feet to the four round holes in the chassis bottom 4 Place the switch with upside up on the workbench Grounding the switch WARNING Correctly connecting the gr...
Page 26: ...e the grounding cable provided with the switch to connect the switch to the grounding strip Connecting the grounding cable to the chassis 1 Remove the grounding screw from the grounding hole in the ch...
Page 27: ...l tube into the earth ground to act as a grounding conductor The dimensions of the angle iron must be a minimum of 50 50 5 mm 1 97 1 97 0 20 in The steel tube must be zinc coated and its wall thicknes...
Page 28: ...thod Power supply model Installation method CA 70A12 PSR75 12A PSR150 D1 See Installing removing a power supply 1 PSR180 56A PSR360 56A PSR560 56D PSR720 56A PSR1110 56A PSR600 54A B PSR920 54A B PSR1...
Page 29: ...r supply removing the power supply causes power down of the switch If you are not to install a new power supply after removing the old one install a filler panel in the slot in time Use a torque of 5...
Page 30: ...ve screw cannot be tightly fastened verify the installation of the power supply As a best practice use a torque of 5 kgf cm 0 49 Nm to fasten the captive screws 6 Install the filler panel over the emp...
Page 31: ...oval procedure A PSR360 56A power supply is used as an example Installing a power supply 1 Wear an ESD wrist strap Make sure the strap makes good skin contact and is reliably grounded 2 Remove the fil...
Page 32: ...insert the power supply gently If you encounter a hard resistance when inserting the power supply pull out the power supply and insert it again Figure 22 Installing a power supply Figure 23 Installati...
Page 33: ...eaker is off before installation Table 11 Power cord connection procedures at a glance Power supply model Available power source Connection procedure reference Built in power supply AC power source Co...
Page 34: ...makes good skin contact and is reliably grounded 2 Plug the female connector of the power cord into the power receptacle on the power supply as shown in Figure 25 3 Use a cable tie to secure the power...
Page 35: ...2 Attach the power cord retainer clip supplied with the power supply into the two holes next to the AC input power receptacle on the power supply and pull the retainer clip leftwards see Figure 27 3 C...
Page 36: ...s wires The power cord connection procedure is the same for the PSR150 D1 and PSR560 56D power supplies The following procedure uses a PSR150 D1 power supply as an example To connect the power cord fo...
Page 37: ...source For a PSR360 56A PSR720 56A or PSR1110 56A power supply you can connect the power cord only to an AC power source For a PSR180 56A PSR600 54A B PSR920 54A B or PSR1600 54A B power supply you ca...
Page 38: ...22...
Page 39: ...connection DB9 to RJ45 console cable DB 9 female connector RJ 45 connector USB to RJ45 console cable USB connector RJ 45 connector The signal pinout for a DB9 to RJ45 console cable depends on the vend...
Page 40: ...onnect the RJ 45 connector to the serial console port on the switch Connecting a USB to RJ45 console cable IMPORTANT To use a USB to RJ45 console cable to connect the switch to a configuration termina...
Page 41: ...file Read me in the Windows folder to check whether the Windows system of the configuration terminal supports the driver 3 If the Windows system supports the driver install PL23XX M_LogoDriver_Setup_...
Page 42: ...such as TeraTermPro on your configuration terminal You can use the emulator program to connect a network device a Telnet site or an SSH site For more information about the terminal emulator programs...
Page 43: ...as software upgrade and file management The Boot ROM interface and menu options differ with software versions For more information about Boot ROM menu options see the software matching release notes...
Page 44: ...setup flowchart To set up an IRF fabric Step Description 1 Plan IRF fabric setup Plan the installation site and IRF fabric setup parameters Planning IRF fabric size and the installation site Identifyi...
Page 45: ...switches Plan the installation site depending on your network solution as follows Place all IRF member switches in one rack for centralized high density access Distribute the IRF member switches in di...
Page 46: ...of one physical port to it When connecting two neighboring IRF member switches you must connect the physical ports of IRF port 1 on one switch to the physical ports of IRF port 2 on the other switch...
Page 47: ...e two SFP ports with the highest numbers as IRF ports Using these ports as IRF ports can prevent issues such as IRF split because IRF protocol packets from these ports can be forwarded in a queue with...
Page 48: ...nection schemes by using SFP cables and SFP transceiver modules and fibers All these schemes use a ring topology IMPORTANT In these schemes all physical IRF ports are located on the same side If physi...
Page 49: ...ic IRF settings For more information about configuring basic IRF settings see IRF configuration in the configuration guide for the switch Connecting the physical IRF ports Connect the IRF member switc...
Page 50: ...a reboot display irf configuration Display IRF fabric topology information display irf topology NOTE To avoid IP address collision and network problems configure a minimum of one multi active detectio...
Page 51: ...nge and the power supply has good ventilation Overtemperature can cause the power supply to stop working and enter protection mode 5 If the issue persists contact H3C Support Removable power supply fa...
Page 52: ...issue occurs contact H3C Support Configuration terminal display issues If the configuration environment setup is correct the configuration terminal displays booting information when the switch is powe...
Page 53: ...3 Data bits 8 Stop bits 1 Parity None Flow control None 2 If the issue persists contact H3C Support...