H3C S3100 Series Ethernet Switches
Installation Manual
Hangzhou H3C Technologies Co., Ltd.
http://www.h3c.com
Manual Version:
20090601-C-1.06
Page 1: ...H3C S3100 Series Ethernet Switches Installation Manual Hangzhou H3C Technologies Co Ltd http www h3c com Manual Version 20090601 C 1 06...
Page 2: ...V2 G Vn G PSPT XGbus N Bus TiGem InnoVision and HUASAN are trademarks of Hangzhou H3C Technologies Co Ltd All other trademarks that may be mentioned in this manual are the property of their respective...
Page 3: ...ht occur during the installation and the booting of an S3100 Series Ethernet Switch and the related solution 7 Appendix Lightning Protection of the Switch Introduces lightning protection of S3100 Seri...
Page 4: ...ocumentation set includes the following Manual Description H3C S3100 Series Ethernet Switches Operation Manual It is used for assisting the users in data configurations and typical applications H3C S3...
Page 5: ...ntal Protection This product has been designed to comply with the requirements on environmental protection For the proper storage use and disposal of this product national laws and regulations must be...
Page 6: ...EI 1 23 S3100 16TP PWR EI 1 25 S3100 8TP PWR EI 1 27 S3100 26C EPON EI 1 28 S3100 16C EPON EI 1 29 S3100 8C EPON EI 1 30 Introduction to Front Panel LEDs 1 31 Front Panel LEDs of the S3100 T SI S3100...
Page 7: ...4 2 Setting Terminal Parameters 4 2 Booting Switch 4 5 Checking Before Powering on the Switch 4 5 Powering on the Switch 4 5 Changing the Startup Mode 4 6 5 Boot ROM and Host Software Loading 5 1 Int...
Page 8: ...S3100 16C SI z S3100 26C SI S3100 TP EI z S3100 8TP EI z S3100 16TP EI z S3100 26TP EI S3100 TP PWR EI z S3100 8TP PWR EI z S3100 16TP PWR EI z S3100 26TP PWR EI H3C S3100 Series Ethernet Switches S31...
Page 9: ...90 VAC to 264 VAC 47 Hz to 63Hz PoE as powered device Not supported Not supported Not supported Not supported System power consumption full load 24 W 16 W 14 W 10W Fan None None None None Operating t...
Page 10: ...auto sensing 10 100Base TX Ethernet port 8 auto sensing 10 100Base TX Ethernet port Number of expansion slots 2 2 1 Number of management ports 1 console port Supported expansion interface module type...
Page 11: ...itch supports 100Base TX PD interface module Notice that S3100 16C SI DC powered switch can accommodate only one PD interface module z The PoE configuration is on the remote power source device on the...
Page 12: ...o 60 VDC z Input voltage range 36 VDC to 72 VDC PoE as powered device Not supported Not supported Not supported System power consumption full load 17W 15W 12W Fan None None None Operating temperature...
Page 13: ...EI and S3100 8TP PWR EI Ethernet switches provide an over temperature protection mechanism When the internal temperature exceeds 65 C 149 F they will stop providing power from all ports When the tempe...
Page 14: ...Switches S3100 52TP SI Front panel Each S3100 52TP SI Ethernet switch provides forty eight auto sensing 10 100Base TX Ethernet ports two auto sensing 10 100 1000Base T Ethernet ports and two 100 1000...
Page 15: ...ted voltage range 100 VAC to 240 VAC 50 Hz 60 Hz z Input voltage range 90 VAC to 264 VAC 47 Hz to 63 Hz Cooling system The S3100 52TP SI cools off naturally S3100 26TP SI Front panel S3100 26TP SI Eth...
Page 16: ...f an S3100 26TP SI Ethernet switch Figure 1 4 Rear panel of an S3100 26TP SI Ethernet switch 1 2 1 Grounding screw 2 AC input terminal block Power system S3100 26TP SI Ethernet switches support AC inp...
Page 17: ...Base T port 5 Console port 6 100 1000Base X SFP port 7 LINK ACT LED green 8 Power LED PWR For details about LEDs on the front panel refer to section Front Panel LEDs of the S3100 TP SI and S3100 TP EI...
Page 18: ...switch 1 2 4 5 6 7 8 3 7 1 Auto sensing 10 100Base TX port Speed LED green 2 Auto sensing 10 100Base TX port 3 Combo port Speed LED green 4 Auto sensing 10 100 1000Base T port 5 Console port 6 100 10...
Page 19: ...Port status LED right green 6 10 100 Base TX port 7 10 100 1000 Base T port 8 Console port 9 LINK LED green 10 ACT LED yellow 11 Mode button For details about LEDs on the front panel refer to section...
Page 20: ...ort status LED right green 6 10 100 Base TX port 7 10 100 1000 Base T port 8 Console port 9 LINK LED green 10 ACT LED yellow 11 Mode button For details about LEDs on the front panel refer to section F...
Page 21: ...status LED left yellow 5 Port status LED right green 6 10 100 Base TX port 7 10 100 1000 Base T port 8 Console port 9 LINK LED green 10 ACT LED yellow 11 Mode button For details about LEDs on the fron...
Page 22: ...ernet switch 1 Power LED 2 A L LED 3 D S LED 4 Port status LED left yellow 5 Port status LED right green 6 10 100Base TX port 7 Expansion slot 8 Console port 9 Mode button z With a PoE card inserted i...
Page 23: ...o 60 VDC z Input voltage range 36 VDC to 72 VDC Cooling system The S3100 26C SI cools off naturally S3100 16C SI Both AC powered switches and DC powered switches are available to this model Front pane...
Page 24: ...net switch 1 AC power socket 2 Grounding screw Figure 1 20 shows the rear panel of an S3100 16C SI DC powered Ethernet switch Figure 1 20 Rear panel of an S3100 16C SI DC powered Ethernet switch 1 DC...
Page 25: ...Base TX port 7 Expansion slot 8 Console port 9 Mode button For details about LEDs on the front panel refer to section Front Panel LEDs of the S3100 T SI S3100 C SI S3100 TP PWR EI S3100 C EPON EI Seri...
Page 26: ...000Base X SFP ports and one console port Each SFP port and the corresponding auto sensing 10 100 1000Base T Ethernet port form a Combo port For each Combo port either the SFP port or the corresponding...
Page 27: ...hes z Rated voltage range 48 VDC to 60 VDC z Input voltage range 36 VDC to 72 VDC Cooling system The S3100 26TP EI cools off naturally S3100 16TP EI Both AC powered switches and DC powered switches ar...
Page 28: ...TP SI and S3100 TP EI Series Rear panel Figure 1 28 shows the rear panel of an S3100 16TP EI AC powered Ethernet switch Figure 1 28 Rear panel of an S3100 16TP EI AC powered Ethernet switch 1 2 1 Grou...
Page 29: ...Ethernet port form a Combo port For the Combo port either the SFP port or the 10 100 1000Base T Ethernet port can be used at a time S3100 8TP EI Ethernet switches have the same front panel as shown in...
Page 30: ...o 63 Hz 2 S3100 8TP EI DC powered Ethernet switches z Rated voltage range 48 VDC to 60 VDC z Input voltage range 36 VDC to 72 VDC Cooling system The S3100 8TP EI cools off naturally S3100 26TP PWR EI...
Page 31: ...panel refer to section Front Panel LEDs of the S3100 T SI S3100 C SI S3100 TP PWR EI S3100 C EPON EI Series Rear panel Figure 1 34 Rear panel of an S3100 26TP PWR EI Ethernet switch 1 2 3 1 AC power...
Page 32: ...SFP port and the corresponding 10 100 1000Base T Ethernet port form a Combo port For each Combo port either the SFP port or the corresponding 10 100 1000Base T Ethernet port can be used at a time Fig...
Page 33: ...located at the rear end of the left side panel as shown in Figure 1 37 Figure 1 37 Security slot on left side panel of an S3100 16TP PWR EI Ethernet switch 1 1 Security slot If the left screw hole abo...
Page 34: ...1 2 3 4 5 6 7 8 1 Auto sensing 10 100Base TX Ethernet port status LED 2 LINK LED for Combo port 3 Console port 4 Power LED PWR 5 A L LED 6 D S LED 7 Mode button 8 ACT LED for Combo port For details a...
Page 35: ...shows the front view of the S3100 26C EPON EI Figure 1 40 Front panel of the S3100 26C EPON EI 1 Power Led PWR 2 A L LED 3 D S LED 4 Port status LED left yellow 5 Port status LED right green 6 10 100...
Page 36: ...e 1000 Mbps uplink PON port and one console port Figure 1 42 shows the front panel of the S3100 16C EPON EI Figure 1 42 Front panel of the S3100 16C EPON EI 1 Power Led PWR 2 A L LED 3 D S LED 4 Port...
Page 37: ...8 x 10 100Base TX Ethernet ports one 1000 Mbps uplink PON port and one console port Figure 1 44 shows the front panel of the S3100 8C EPON EI Figure 1 44 Front panel of the S3100 8C EPON EI 1 Power L...
Page 38: ...ed on Power LED PWR OFF The switch is powered off Auto sensing 10 100Base TX Ethernet port status LED There are two port status LEDs on both sides yellow LED on the left and green LED on the right of...
Page 39: ...f you press the Mode button the D S LED will be on After that if you press the Mode button again within 45 seconds the A L LED will be on again Otherwise the A L LED will automatically be on 45 second...
Page 40: ...Act LED of the Combo port on the S3100 TP SI and the S3100 TP EI series see Table 1 12 When the port is connected correctly the Speed LED indicates the operating speeds of the Combo port as shown in T...
Page 41: ...dules to insert For the models of SFP modules see Table 1 16 Table 1 16 SFP modules supported by S3100 Ethernet switches Type Model 100 Mbps SFP module z SFP FE SX MM1310 A z SFP FE LX SM1310 A 1000 M...
Page 42: ...al 1000Base PX20 LS6M2PU1SB All models of ONU modules look alike Figure 1 46 and Figure 1 47 depict the LS6M2PU1SB Figure 1 46 Appearance of the LS6M2PU1SB Figure 1 47 Front panel of the LS6M2PU1SB 1...
Page 43: ...dule refer to section Installing an Expansion Interface Module Table 1 19 describes the LED indications Table 1 19 Description of ONU module LEDs LED Status Meaning ON The port is connected properly L...
Page 44: ...ole and the ventilation hole of the switch for heat dissipation of the switch chassis z The cabinet or the workbench takes good ventilation and heat dissipation system z The cabinet or the desk is sol...
Page 45: ...s The equipment room should be protected from the intrusion of harmful gases such as SO2 H2S NH3 and Cl2 The limits of these kinds of harmful gas are shown in the following table Table 2 2 Limits on h...
Page 46: ...s is operating avoid staring into the optical interface because the high energy laser beam emitted from the optical fiber may hurt your eyes Installation Tools These installation tools are not shipped...
Page 47: ...ears and rear mounting ears z Use front mounting ears and guide rails The installation methods of a switch depend on the depth and width of the switch For the specific installation methods see Table...
Page 48: ...inet Use one M6 screw 2 Screw hole used to fix the switch to the mounting ear Figure 3 2 shows the appearance of a rear mounting ear Figure 3 2 Appearance of a rear mounting ear 1 Screw hole used to f...
Page 49: ...S3100 8C EPON EI 42 326 200 mm 1 65 12 8 7 9 in Optional S3100 52TP SI 43 6 440 230 mm 1 7 17 3 9 1 in Standard S3100 26TP SI S3100 26TP EI 43 6 440 160 mm 1 7 17 3 6 3 in Standard S3100 16TP SI S310...
Page 50: ...bstitute for guide rails in the case of other cabinet depths Use front mounting ears to install a switch Follow these steps to mount a switch into a 19 inch standard cabinet 1 Wear an ESD preventive w...
Page 51: ...re 3 4 4 Place the switch on the tray horizontally slide the tray into the cabinet and fix the other end of mounting ears to the front brackets with crews and captive nuts as shown in Figure 3 5 Use f...
Page 52: ...ition according to the actual requirements The rear mounting ears tightly contacted with the load bearing screws can support the switch 4 Select a position to install the switch and fix the rear mount...
Page 53: ...w used to fix rear mounting ears to rear brackets 7 Front mounting ear After the switch is pushed into the cabinet ensure that the upper edge of rear mounting ears is tightly contacted with the load b...
Page 54: ...nt mounting ears to front brackets 5 Front mounting ear 6 Front square holed bracket Use front mounting ears and guide rails to install a switch Follow these steps to install a switch into a 19 inch s...
Page 55: ...2 Ensure that the bottom side of the guide rails and the switch are in close contact Figure 3 12 Install front mounting ears and guide rails 1 Front panel 5 Fix the other end of front mounting ears to...
Page 56: ...heat dissipation z No heavy object is placed on the switch z S3100 SI and S3100 TP EI Series Ethernet Switches are designed with no fan Therefore you should install them in a drafty environment and ke...
Page 57: ...with a distance of X mm z The distance X between holes varies with devices For specific distances see Table 3 4 z Drill two holes according to the sizes of anchor kits and screws so that anchor kits...
Page 58: ...cal to the ground Magnet Mounting The following two models support magnet mounting z S3100 8TP PWR EI z S3100 16TP PWR EI Introduction to magnetic mounting accessories A set of magnetic mounting acces...
Page 59: ...the permanent magnet and the switch are fastened reliably z Remove the cushion if any from the dent before installation z To ensure the firmness of installation be sure to use four permanent magnets t...
Page 60: ...luenced by magnetic fields away from magnets Otherwise faults may occur to these electronic devices Connecting Grounding Cable z Correctly connecting the switch ground wire is crucial to the lightning...
Page 61: ...20 in of insulation sheath using a wire stripper and then insert the naked metal part through the black insulation covering into the end of the OT terminal Two OT terminals are provided with the PGND...
Page 62: ...angel iron or steel tube and treat the joint for corrosion protection Figure 3 21 Ground the switch by burying the grounding conductor into the earth 1 Grounding screw 2 PGND cable 3 Earth 4 Joint 5...
Page 63: ...vailable ground the switch through the return wire RTN of the DC power supply In this case make sure this RTN wire is well connected to the ground at the DC output of the DC power cabinet Figure 3 23...
Page 64: ...C power cable 1 Connect one end of the grounding cable delivered with the switch to the grounding screw on the rear of the chassis and the other end to the ground nearby 2 Connect one end of the power...
Page 65: ...onnected Before powering on the switch you should properly connect the grounding cable Connecting DC Power Cable DC power cable connection for S3100 C SI S3100 TP EI DC powered Ethernet switch Figure...
Page 66: ...PWR EI Ethernet switch Figure 3 27 RPS DC power socket for S3100 26TP PWR EI Ethernet switch Working ground Voltage input 52 VDC to 56 VDC NULL Reserved 1 Connect one end of the grounding cable delive...
Page 67: ...ront panel of the switch is ON If yes the power is properly connected z Before powering on the switch you must properly connect the grounding cable z The DC power cable should be less than 3 meters lo...
Page 68: ...ional interface module pay attention to the following points z Do not touch the surface mounted components directly with your hands z Do not use too much force in the operation z After removing an int...
Page 69: ...he ONU subcard Step 3 Plug the optical connector into the PON interface of the ONU subcard Installation Verification After completing the installation check that z The correct power is used z The grou...
Page 70: ...work diagram for configuration environment setup Connecting the Console Cable Console Cable The console cable is an 8 core shielded cable At one end of the cable is a crimped RJ 45 connector to be con...
Page 71: ...switch you are recommended to connect the DB 9 connector of the console cable to the PC before connecting the RJ 45 connector to the switch When disconnecting a PC from a powered on switch you are rec...
Page 72: ...HyperTerminal 2 Type in the name of the new connection in the connection description interface and click OK The system pops up the following interface Select the serial port to be used from Connect u...
Page 73: ...s and the system enters the following interface Figure 4 6 HyperTerminal Choose Properties in the HyperTerminal dialog box to enter the properties window Click Settings to enter the following properti...
Page 74: ...roperly connected the terminal which can be a PC used for configuration has been started and the configuration parameters have been set Powering on the Switch All the S3100 series Ethernet switches ha...
Page 75: ...d BOOT MENU 1 Download application file to flash 2 Select application file to boot 3 Display all files in flash 4 Delete file from flash 5 Modify bootrom password 6 Enter bootrom upgrade menu 7 Skip c...
Page 76: ...to full startup mode Yes or No Y N Enter Y and the system gives the following prompts Setting startup mode done BOOT MENU 1 Download application file to flash 2 Select application file to boot 3 Disp...
Page 77: ...0x80100000 Initialize LS41LTSGB0 OK SDRAM fast selftest OK Flash fast selftest OK Switch chip selftest OK Slot 1 1 1 has no module PHY selftest OK Please check port leds FINISHED User interface aux0 i...
Page 78: ...port z TFTP via Ethernet port z FTP via Ethernet port You can load the software remotely by using z FTP z TFTP Boot ROM software version should be compatible with the host software version when you lo...
Page 79: ...ss Ctrl B within five seconds after the information Press Ctrl B to enter Boot Menu appears Otherwise the system starts to decompress the program and if you want to enter the Boot Menu at this time yo...
Page 80: ...m proceeds to send another packet otherwise the receiving program sends a negative acknowledgement packet and the sending program retransmits the packet Loading Boot ROM software Follow these steps to...
Page 81: ...below and proceed to Step 6 directly In this case the system will not display the above information Step 4 Select File Properties in the HyperTerminal window click Configuration in the popup dialog bo...
Page 82: ...nd takes effect only after you disconnect and reconnect the terminal emulation program Step 6 Press Enter to start downloading the program The system displays the following information Now please star...
Page 83: ...the last step if you have chosen 9600 bps In this case the system displays the prompt BootROM is updating now done instead of the prompt Your baudrate should be set to 9600 bps again Press enter key w...
Page 84: ...data stream transfer service Loading Boot ROM software Figure 5 6 Local loading using TFTP PC TFTP Client TFTP Server Switch Console port Ethernet port Step 1 As shown in Figure 5 6 connect the switc...
Page 85: ...ing done Loading host software Follow these steps to load the host software of the switch Step 1 Select 1 in Boot Menu The system displays the following information 1 Set TFTP protocol parameter 2 Set...
Page 86: ...press 6 or Ctrl U and then press Enter to enter the BootROM update menu shown below Bootrom update menu 1 Set TFTP protocol parameter 2 Set FTP protocol parameter 3 Set XMODEM protocol parameter 0 Ret...
Page 87: ...ROM and host software remotely Remote Loading Using FTP As shown in Figure 5 8 a PC is used as both configuration device and FTP server You can telnet to the switch and then execute the FTP commands t...
Page 88: ...M and host software loading is completed Pay attention to the following z Host software loading takes effect only after you restart the switch with the reboot command z If the space of the flash memor...
Page 89: ...tch IP addresses z Correct name of the software to be loaded z Correct working path of TFTP server 3 When using FTP verify that you have provided z Correct server and switch IP addresses z Correct nam...
Page 90: ...al or the displayed characters will be totally illegible Troubleshooting when there is no terminal display If there is no output information after the configuration is powered on please check that z T...
Page 91: ...of Contents Appendix A Lightning Protection of the Switch A 1 Installation of Lightning Arrester for AC Power Socket Strip with Lightning Protection A 1 Installation of Lightning Arrester for Network...
Page 92: ...u can use cable clips and screws to fasten the lightning arrester for AC power on the cabinet workbench or the wall of equipment room Figure A 1 Diagram of lightning arrester 1 Working LED green On me...
Page 93: ...the arrester is set to the reverse polarity In this case you should open the power socket of arrester to correct polarity After that if the red LED still alarms it means that the arrester is not well...
Page 94: ...Step 5 Use the nylon ties to bundle the cables neatly Figure A 2 Installation diagram of lightning arrester for network port Switch Network cable indoors Power input Network cable led into from outdo...