2-14
NOTE:
The chassis views and power supply and grounding terminal positions in the following figures are for
illustration only.
Grounding the switch with a grounding strip
WARNING!
Connect the grounding cable to the grounding system in the equipment room. Do not connect it to a
fire main or lightning rod.
If a grounding strip is available at the installation site, use the grounding strip to ground the switch.
To ground the switch by using a grounding strip:
1.
Attach the ring terminal end of the grounding cable to the grounding hole in the switch.
a.
Remove the grounding screw from the grounding hole in the rear panel of the switch.
b.
Attach the grounding screw to the ring terminal of the grounding cable.
c.
Use a screwdriver to fasten the grounding screw into the grounding screw hole.
Figure2-12 Attaching the grounding cable to the grounding hole of the switch
(S1850-52X switch)
(1) Grounding screw
(2) Ring terminal
(3) Grounding sign
(4) Grounding hole
(5) Grounding cable
2.
Connect the other end of the grounding cable to the grounding strip.
a.
Use the needle-nose pliers to bend the bare wire.
b.
Hook the grounding cable to the post on the grounding strip, and use the hex nut to secure
the cable to the post.
5
1
2
3
4