Fabric module failure
Symptom
The LEDs for a fabric module are in the following states:
•
On the MPU, the slot status LED for the fabric module is steady red or flashing red.
•
On the fan tray, the RUN LED for the fabric module is off.
{
On the S12516R and S12508R fan trays, the RUN and ALM LED pairs correspond to the
fabric module slots from left to right.
{
On the S12504R fan tray, the extended lines of the RUN and ALM LED pairs correspond to
the fabric module slots from left to right.
Figure 5-1 Corresponding relations between the LEDs on the S12504R fan trays and
fabric module slots
(1) LEDs for the fabric module slot 6
(2) LEDs for the fabric module slot 8
(3) Fabric module slot number
(4) LEDs for the fabric module slot 9
(5) LEDs for the fabric module slot 11
(6) Fabric module slot number
•
On the fabric module, the LED is red.
Solution
To resolve the issue:
1.
Verify that the MPU and the fan tray are operating correctly. For more information, see "
."