![H3C S12500G-AF Series Installation Manual Download Page 70](http://html1.mh-extra.com/html/h3c/s12500g-af-series/s12500g-af-series_installation-manual_3629219070.webp)
7-6
Figure7-2 Corresponding relations between the LEDs on the S12504G-AF fan trays
and fabric module slots
(1) LEDs for the fabric module slot 6
(2) LEDs for the fabric module slot 8
(3) Fabric module slot number
(4) LEDs for the fabric module slot 9
(5) LEDs for the fabric module slot 11
•
On the fabric module, the RUN/ALM LED is red.
Solution
To resolve the issue:
1.
Verify that the MPU and the fan tray are operating correctly. For more information, see "
2.
Verify that the fabric module is compatible with the system software. Upgrade the system
software if it does not support the fabric module.
3.
Calculate the total power consumption, and make sure your power modules can provide
enough power. For more information, see
H3C S12500G-AF Switch Series Hardware
Information and Specifications
.
4.
Remove and reinstall the fabric module to make sure the module is installed securely. You also
need to verify that the ejector levers are locked securely in place. For more information, see
"Installing fabric modules."
5.
If the switch has empty fabric module slots, install the module in an empty fabric module slot. If
the module operates correctly, the previous slot is faulty.
6.
If the issue persists, contract H3C Support.
Interface failure
Symptom
The LED for the interface is off.
NOTE:
A management Ethernet port has two LEDs, LINK and ACT. When the LINK LED is off, the
management Ethernet port fails.
2
3
1
5
4
Summary of Contents for S12500G-AF Series
Page 32: ...3 15 Figure3 16 Connecting the grounding cable to a grounding strip 1 2 4 3 6 5 ...
Page 49: ...4 16 Figure4 16 Connecting an SFP DAC cable 1 Pull latch 2 Connector 1 2 ...
Page 92: ...A 12 FigureA 14 Example of a device label ...
Page 104: ...C 6 FigureC 5 Securing the chassis to the pallet base S12504G AF switch 1 1 2 2 1 ...