103
Fan trays
The S12500-X switch comes with two fan trays installed.
Order the fan trays compatible with your switch if necessary.
Table 34
Fan tray specifications
Chassis model
Applicable fan
tray
Maximum
air flow rate
Number
of fans
Fan diameter
Maximum
rotating speed
•
S12510-X AC
•
S12510-X DC
S12510-X fan
tray
1750 CFM
5
200 mm (7.87 in) 7700 RPM
•
S12516-X AC
•
S12516-X DC
S12516-X upper
fan tray FAN1
2100 CFM
17
120 mm (4.72 in) 6300 RPM
92 mm (3.62 in)
8100 RPM
S12516-X lower
fan tray FAN2
1700 CFM
13
120 mm (4.72 in) 6300 RPM
92 mm (3.62 in)
8100 RPM
Air filters
CAUTION:
Clean air filters a minimum of once every three months to guarantee adequate ventilation and avoid
over-temperature.
The air filter is an optional accessory.
You can install air filters at the air inlet vents of the chassis to prevent dust from entering the switch.
•
S12510-X AC & S12510-X DC switches
—Air inlet vents are located below the plastic panel at the
lower part of the front panel.
•
S12516-X AC & S12516-X DC switches
—Air inlet vents are located at the left side of the chassis and
below the plastic panel at the lower part of the front panel.
Transceiver modules
The switch supports transceiver modules. You can order transceiver modules according to the transceiver
modules supported by the LPU interfaces. For more information, see
and
.
The switch supports the following transceiver modules:
•
10-Gigabit SFP+ modules listed in
.
•
10-Gigabit SFP+ copper cables listed in
.
•
•
QSFP+ modules listed in
.
•
QSFP+ copper cables listed in
•
QSFP+ to SFP+ copper cables listed in
.
•
CFP modules listed in
Summary of Contents for S12500-X
Page 35: ...26 Figure 20 Grounding the switch through the RTN wire of the DC power module...
Page 80: ...71 Figure 51 Replacing an LPU 1 1 Loosen the captive screw 2 Pull the ejector levers outward...
Page 138: ...129 Figure 75 CXP fiber cable 1 Connector 2 Pull latch 1 2...
Page 152: ...143 Figure 91 Cable routing from the left side for an S12510 X AC S12510 X DC switch...