Page 2: ... subject to change without notice All contents in this document including statements information and recommendations are believed to be accurate but they are presented without warranty of any kind express or implied H3C shall not be liable for technical or editorial errors or omissions contained herein Environmental protection This product has been designed to comply with the environmental protect...

Page 3: ...ecifications 4 Power module configuration 4 Installing and removing the power module 6 Installing the power module 6 Installing the power module 6 Connecting the power cord 9 Removing a power module 11 Removing the power cord 12 Removing the power module 12 ...

Page 4: ...ltage output short circuit output under current output over current and overheat Redundancy The power modules can operate in N 1 or N N redundancy For more information see Power module configuration Hot swapping You can install or remove a power module when the device is operating The power module shuts down automatically when its temperature exceeds the acceptable range When the temperature retur...

Page 5: ...2 Front panel Figure 1 Front panel 1 Power input LED AC OK 2 Handle 3 AC input receptacle 4 Latch 5 Power output LED DC OK 6 Air outlet vents LEDs Each PSR3000 54A power module has two LEDs ...

Page 6: ...tput LED DC OK Green Normal DC output Red DC output failure An alarm condition occurs for example output short circuit output over current output over voltage output under voltage or remote shutdown The power module has entered the protected state Orange High temperature NOTE After the circuit breaker of the power module is switched off the LEDs on the power module will remain on for a while ...

Page 7: ...VAC Dimensions H W D 41 100 332 mm 1 61 3 94 13 07 in Ambient temperature Operating temperature 10 C to 50 C 14 F to 122 F Storage temperature 40 C to 70 C 40 F to 158 F Power module configuration Follow these guidelines to configure power modules for the device Determine the total number of power modules based on the actual power consumption the power module slot number and power redundancy desig...

Page 8: ... of power module slots When one mains power input is provided you can configure the power modules in N 1 or N N redundancy N 1 or N N must be not greater than the total number of power module slots For easy usage and maintenance configure a circuit breaker for each power input The rated current of the circuit breaker must be a minimum of 20 A ...

Page 9: ...ow the procedures in Figure 2 to install a power module Figure 2 Power module installation procedure Before the installation prepare an ESD wrist strap and a flat blade screwdriver yourself Installing the power module 1 Wear an ESD wrist strap and make sure the strap makes good skin contact and is correctly grounded ...

Page 10: ...at blade screwdriver through the hole in the handle of the blank panel and pull the blank panel out If the blank panel is as shown in Figure 4 put your forefinger in the hole in the blank panel and pull the blank panel out Skip this step if the target slot has no blank panel installed Figure 3 Removing a blank panel 1 ...

Page 11: ...tch is below the handle 5 Holding the handle of the power module with one hand and supporting the bottom of the power module with the other slide the power module along the guide rails into the slot until you hear a click The power module is foolproof If the power module is oriented incorrectly you cannot install the power module into the slot If you encounter a hard resistance while inserting the...

Page 12: ...9 Figure 5 Installing a power module Connecting the power cord WARNING Make sure each power cord has a separate circuit breaker Turn off the circuit breaker before you connect the power cord ...

Page 13: ...AC power cord connector into the AC input receptacle of the power module 2 Use a removable cable tie or self adhesive cable tie to secure the power cord to the handle of the power module Route the power cords of the left power modules to the left side Route the power cords of the right power modules to the right side Figure 6 Securing the power cord with a C19 angled connector by using a removable...

Page 14: ... cord into an AC power receptacle and turn on the circuit breaker 4 Verify that the power input LED is ON If the LED is on the power cord is correctly connected If the LED is OFF troubleshoot the installation process Removing a power module To avoid device damage and bodily injury follow the procedures in Figure 8 to remove the power module ...

Page 15: ...rn off the circuit breaker of the power cord 2 Wear an ESD wrist strap and make sure the strap makes good skin contact and is correctly grounded 3 Remove the cable tie and pull the power cord out Removing the power module CAUTION Before you insert a removed power module into a power module slot make sure the LEDs on the power module are off ...

Page 16: ... out of the slot 2 As shown in Figure 9 grasping the handle of the power module with one hand and supporting the bottom of the power module with the other hand pull the module slowly along the guide rails out of the slot Figure 9 Removing a power module 3 Place the power module on an antistatic mat 4 Install the blank panel in the power module slot ...