2
IMPORTANT:
After a power module is latched, it cannot restore power supply
automatically after the problems are resolved. Follow this procedure to
restore the power module operation:
1.
Disconnect the power cord from the external power supply system.
2.
Disconnect the power cord from the power module.
3.
Wait a few seconds and then connect the power cord to the power
module.
4.
Connect the power cord to the external power supply system.
Technical specifications
Table 2 Technical specifications
Item Specifications
Rated voltage range
•
PSR150-A1
{
AC input: 100 VAC to 240 VAC @ 50 Hz or
60 Hz
{
DC input: 240 VDC
•
PSR150-D1: –48 VDC to –60 VDC
Max voltage range
•
PSR150-A1
{
AC input: 90 VAC to 264 VAC @ 47 Hz or
63 Hz
{
DC input: 192 to 290 VDC
•
PSR150-D1: –36 VDC to –72 VDC
Output voltage
12 V
Max output current
12.5 A
Max output power
150 W
Dimensions (H × W × D)
41.1 × 101.6 × 177 mm (1.62 × 4 × 6.97 in)
Operating temperature
–5°C to +55°C (25°F to 131°F)
Storage temperature