H3C NSQM1FWDFGC1 Manual Download Page 1

Manual version: 6PW105-20190315 

BOM: 3123A1BU

 

H3C SecPath M9000 NSQM1FWDFGC1 firewall 

module 

1  Identifier 

The module identifier NSQM1FWDFGC1 is at the upper right corner of the front panel. 

2  About the module 

The NSQM1FWDFGC1 firewall module is developed for H3C SecPath M9000 security gateways. 
The module provides features including firewall, VPN, content filtering, and NAT. By using this 
module on an M9000 gateway, you can enhance network security capabilities without changing the 
network topology. 

3  Specifications 

The module has one console port, one USB port, one GE copper port, and a hard disk slot. 

Figure 1 Front panel 

 

(1) Hard disk slot 

(2) Console port (CONSOLE)  

(3) GE copper port (10/100/1000BASE-T) 

(4) USB port (reserved) 

(5) Hard disk LED (HD) 

(6) System status LED (SYS) 

(7) Ejector lever 

(8) Captive screw 

 

Table 1 Module specifications 

Item Specification 

Flash 

8 MB Nor Flash 

Memory 

Four memory slots 
Standard configuration: 32 GB (four 8-GB VLP RDIMMs) 
You must install the DDR3 SDRAMs in pairs and each pair must have the 
same specifications. 

Micro SD card 

One built-in Micro SD card slot 
Standard configuration: 8 GB 

Dimensions (H × W × D) 

40 ×399 × 352 mm (1.57 × 15.71 × 13.86 in) 

Power consumption 

180 W to 260 W 

Weight 

4.8 kg (10.58 lb) 

Hot swapping 

Supported 

Summary of Contents for NSQM1FWDFGC1

Page 1: ... The module has one console port one USB port one GE copper port and a hard disk slot Figure 1 Front panel 1 Hard disk slot 2 Console port CONSOLE 3 GE copper port 10 100 1000BASE T 4 USB port reserved 5 Hard disk LED HD 6 System status LED SYS 7 Ejector lever 8 Captive screw Table 1 Module specifications Item Specification Flash 8 MB Nor Flash Memory Four memory slots Standard configuration 32 GB...

Page 2: ... you are using see the release notes Table 2 Console port specifications Item Specification Connector RJ 45 Interface standard RS 232 Transmission baud rate 9600 bps default to 115200 bps Transmission medium Asynchronous serial cable Transmission distance 15 m 49 21 ft Services Provides connection to an ASCII terminal Provides connection to the serial port of a local or remote through a pair of mo...

Page 3: ...s might be vertical or horizontal depending on the gateway model When installing the module in a horizontal slot make sure its component side faces up When installing the module in a vertical slot make sure its component side faces left The module installation and removable procedures are the same for horizontal or vertical slots The following procedures install and remove the module in a horizont...

Page 4: ...le to separate the module from the backplane and pull the module slowly out of the chassis along the guide rails 4 Place the module on an anti static workbench with the component side facing up or put it in an anti static bag 5 If you are not to install a new module install a filler panel in the slot to prevent dust and ensure good ventilation in the gateway 6 Software upgrade For information abou...

Reviews: