Installation Manual
H3C SecPath F1800-A Firewall
Chapter 3 Installation
3-2
Caution:
Before installing a SecPath, make sure that:
z
You have read Chapter 2 carefully.
z
What described in Chapter 2 has been met.
3.2 Mounting a SecPath to a Specified Place
3.2.1 Mounting a SecPath into the Rack
Note:
The SecPath can be mounted in N68 cabinet provided by Huawei-3Com.
For N68 cabinet installation in detail, refer to “N68 Cabinet Installation”.
The SecPath is designed to fit the 19-inch standard rack.
Its dimensions are 436.2 mm (Width) ×420 mm (Depth) ×130.5 mm (Height).
Its weight is 20 kg with full configuration.
Follow the steps below to mount a SecPath.
Step 1:
Make confirmation before mounting.
Ensure the rack has been well fixed. The installation position for the SecPath has
been well arranged and there is no obstacle inside the rack or around.
Ensure the equipment is ready for installation and has been placed near the rack,
where the equipment can be moved easily.
Step 2:
Install chassis brackets.
Fix the brackets to both sides of the chassis with M3 screw by a cross screwdriver and
remove cable holder on brackets, as shown in
.