Installation Manual
H3C SecPath F1000-S Firewall
Chapter 2 Preparation for Installation
2-1
Chapter 2 Preparation for Installation
2.1 Site Requirements
The H3C SecPath Series Firewalls must be used indoors. To guarantee the normal
operation and long service life of your firewall, install it in an environment that can meet
the requirements in the following sections.
2.1.1 Temperature/Humidity
The equipment room must maintain adequate temperature and humidity. Long-lasting
high humidity is prone to cause bad insulation and even electricity creepage.
Sometimes the mechanical performance changes of materials, the rustiness and
corrosion of some metal parts are also likely to occur. If the relative humidity is too low,
the captive screws can become loose due to insulation washer contraction. Meanwhile,
the static is likely produced in the dry environments, jeopardizing the CMOS circuit of
the product. The higher the temperature is, the greater the damage to your device.
Long-lasting high temperature can speed up the aging of the insulation materials,
greatly lower the device reliability, and hence significantly shorten its service life.
Table 2-1 lists the temperature and humidity requirements.
Table 2-1
Temperature/humidity requirements in the equipment room
Temperature
Relative humidity
0
°
C to 40
°
C (32
°
F to 104
°
F)
10% to 90% (noncondensing)
2.1.2 Cleanliness
Dust is a hazard to the operating safety of your device. The dust accumulated on the
chassis can cause electrostatic adsorption, one of the sources that cause the poor
contact of connectors or metal contact points. This not only shortens the service life of
your device but also causes communications failures. When the indoor relative
humidity is low, electrostatic adsorption is more likely to happen.
The equipment room must be free of explosion hazards and the electric and magnetic
conductible dust as well. The contents of the dust must be limited to the values shown
in Table 2-2.