110
Setting the global loop protection action
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Configure the global loop
protection action.
loopback-detection global
action
shutdown
By default, the device generates a
log but performs no action on the
port on which a loop is detected.
Setting the loop protection action on a Layer 2 Ethernet
interface
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter Layer 2 Ethernet
interface view.
interface
interface-type
interface-number
N/A
3.
Configure the loop protection
action on the interface.
loopback-detection action
shutdown
By default, the device
generates a log but performs
no action on the port on which
a loop is detected.
Setting the loop protection action on a Layer 2 aggregate
interface
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter Layer 2 aggregate
interface view.
interface bridge-aggregation
interface-number
N/A
3.
Configure the loop protection
action on the interface.
loopback-detection action
shutdown
By default, the device
generates a log but performs
no action on the port on which
a loop is detected.
Setting the loop detection interval
With loop detection enabled, the device sends loop detection frames at a specified interval. A shorter
interval offers more sensitive detection but consumes more resources. Consider the system
performance and loop detection speed when you set the loop detection interval.
To set the loop detection interval:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Set the loop detection
interval.
loopback-detection
interval-time interval
The default setting is 30 seconds.