8
information about configuring FC on the switching fabric module, see the relevant configuration
guide and command reference.
2.
Execute the
lsmod | grep qla2xxx
command to verify that the network adapter driver has
been loaded.
Figure 23 Verifying the loading status of the network adapter driver
3.
Execute the
ls /sys/class/fc_host
command to check whether ports of the FC680i
network adapter have been initialized. Execute
the
cat
/sys/class/fc_host/host*/port_state
command to check whether the ports are
Link Up.
Figure 24 Viewing the port status
4.
After associating the storage host with the FC680i's FC port on the storage server, execute the
lsblk
command in the system to verify if new disks exist. If yes, it indicates that FC SAN has
been identified.
If not, execute the
echo 1 > /sys/class/fc_host/hostnum/issue_lip
command to
manually refresh
fc_host
. The
hostnum
argument represents the FC port number. Then,
execute the
lsblk
command.
Figure 25 Verifying if new disks exist
Windows operating system
1.
Configure the FC feature on the FC storage device and the switching fabric module to ensure
that the FC link is available and the relevant port WWPN can be registered correctly. For
information about configuring FC on the switching fabric module, see the relevant configuration
guide and command reference.
2.
Select
Control Panel
>
Hardware
>
Device Manager
. Right click the FC adapter under
Storage controllers
. Select
Scan for hardware changes
.