Sample Wiring Diagrams
These wiring diagrams are intended only as examples of how the relay unit and RFID device may
be installed. Actual installation wiring may differ. The GateKeeper is supplied with stub wiring so
that the system can be bench-tested. Typically, the GateKeeper will be positioned or mounted at or
near the facility reception desk. This enables the desktop reader to be connected, and door
readers to be connected by longer cabling fitted to wall and floor edges. This positioning also
typically allows the GateKeeper to use the same network cable access to the Internet router as
used by the reception computer.
Fail Secure
locks will
LOCK
the door when the power goes off.
Fail Safe
locks will leave the door
UNLOCKED
when the power goes off.
Check with your local fire regulations as to which you should use.
Door lock, door lock power supply, and any Push to Exit buttons are NOT supplied by GymMaster,
and should be sourced in advance by installer.
Note: If you use
Fail Secure locks
, it is
STRONGLY recommended that you have
alternative means by which you can physically unlock the door
in case of outage
(loss of power, or no connection to Internet for a long period, etc).
Door lock
MUST
have its own separate power supply. Do
NOT
use the GateKeeper or
the GateKeeper power supply to power any mag locks or door strike.