REMOTE CONTROL
59
Configure Ethernet Connection
The Ethernet interface can be configured for a number of different
applications. Ethernet can be configured for basic remote control or
monitoring using a web server or it can be configured as a socket
server.
The PSU series supports both DHCP connections so the instrument
can be automatically connected to an existing network or
alternatively, network settings can be manually configured.
Ethernet
configuration
Parameters
For details on how to configure the Ethernet
settings, please see the configuration chapter on
page 4.
MAC Address (display
only)
LAN Enable/Disable
DHCP Enable/Disable IP Address
Subnet Mask
Gateway
DNS Address
Sockets Server
Enable/Disable
Web Server
Enable/Disable
Web Password
Enable/Disable
Web Enter Password
Web Server Configuration
Configuration
This configuration example will configure the PSU
as a web server and use DHCP to automatically
assign an IP address to the PSU.
1.
Connect an Ethernet cable from the
network to the rear panel Ethernet
port.
LAN