GW Instek PEL-3000E Quick Start Manual Download Page 1

DC Electronic Load

 

PEL-3000E

 

QUICK START GUIDE

GW INSTEK PART NO. 82EL-3KE00M

A

1

ISO-9001 CERTIFIED MANUFACTURER

 

S

AFETY INSTRUCTIONS

This section contains the basic safety symbols that may 

appear on the accompanying User Manual CD or on the 

instrument. For detailed safety instructions and 

precautions, please see the Safety Instructions chapter 

in the user manual CD.  

Safety Symbols 

These safety symbols may appear in the user manual or 

on the instrument.  

Warning 

Warning: Identifies conditions or 

practices that could result in injury or 

loss of life. 

Caution 

Caution: Identifies conditions or 

practices that could result in damage 

to the instrument or to other 

properties. 

DANGER High Voltage 

Attention Refer to the Manual 
Earth (ground) Terminal 

Frame or Chassis Terminal 

Do not dispose electronic equipment 

as unsorted municipal waste. Please 

use a separate collection facility or 

contact the supplier from which this 

instrument was purchased. 

Power Cord for the United Kingdom 

When using the instrument in the United Kingdom, 

make sure the power cord meets the following safety 

instructions. 

NOTE: This lead/appliance must only be wired by 
competent persons. 

WARNING: THIS APPLIANCE MUST BE EARTHED 

IMPORTANT: The wires in this lead are coloured in 
accordance with the following code: 

Green/ Yellow: Earth 
Blue: 

Neutral 

Brown: 

Live (Phase) 

As the colours of the wires in main leads may not correspond with 

the coloured marking identified in your plug/appliance, proceed as 

follows: 

The wire which is coloured Green & Yellow must be connected to 

the Earth terminal marked with either the letter E, the earth symbol 

 or coloured Green/Green & Yellow. 

The wire which is coloured Blue must be connected to the terminal 

which is marked with the letter N or coloured Blue or Black. 

The wire which is coloured Brown must be connected to the terminal 

marked with the letter L or P or coloured Brown or Red. 

If in doubt, consult the instructions provided with the equipment or 

contact the supplier. 

This cable/appliance should be protected by a suitably rated and 

approved HBC mains fuse: refer to the rating information on the 

equipment and/or user instructions for details. As a guide, a cable of 

0.75mm

2

 should be protected by a 3A or 5A fuse. Larger conductors 

would normally require 13A types, depending on the connection 

method used. 

Any exposed wiring from a cable, plug or connection that is engaged 

in a live socket is extremely hazardous. If a cable or plug is deemed 

hazardous, turn off the mains power and remove the cable, any 

fuses and fuse assemblies. All hazardous wiring must be 

immediately destroyed and replaced in accordance to the above 

standard. 

G

ETTING STARTED

The Getting Started chapter introduces the instrument’s 

main features, appearance, and set up procedure. 

Overview 

The PEL-3000E is an economic, standalone, high 
performance DC electronic load positioned to test a 
wide range of different power sources. The DC 
electronic load is fully programmable to simulate 
anything from basic static loads to complex dynamic 
loads. The PEL-3000E is extremely robust and capable 
of molding to any test environment. 

Model Line Up 

Model 

Operating 
Voltage (DC)  Current 

Power 

PEL-3031E  1V-150V 

6A (Low range) 

60A (High range) 

300W 

PEL-3032E  2.5V-500V 

1.5A (Low range) 

15A (High range) 

300W 

Main Features 

Performance 

High slew rates of up to 2.5A/μs 

for a fast response speed (PEL-

3031E) 

High resolution – 16 bit 

Features 

7 operating modes: CC, CV, CR,

CP, CC+CV, CR+CV, CP+CV

Fully programmable with normal 

and fast sequences 

Soft start 

Dynamic mode 

OCP, OVP and other protection 

features 

Remote sense 

Integrated meter

Rack-mountable 

Interface 

USB and GPIB 

External voltage or resistance 

control 

Rear panel trigger in/out BNC

Analog external control

Display Overview 

Mode

CC

I Range

H 60A

V Range

L 15V

Function

Static

Configure

0.0000

V

0.000

A

0.00

w

SlewRate

2500

CC B Value

0.000

CC A Value

0.000

LOAD

USB

A Value

Fine

mA/us

A

A

1

2

3

4

5

Description 

1.

Main frame status 

panel 

2.

Operation status 

panel 

3.

Soft keys 

4.

Setting area

5.

Measurement area 

First Time Use Instructions 

Use the following procedures when first using the 

PEL-3000E to power up the instrument, restore the 

factory default settings and check the firmware 

version. Lastly, the Conventions section will introduce 

you to the basic operating conventions used 

throughout the user manual.   

Rear Panel 

1

2

3

4

5

6

7












































Description 

1.

J1 Frame control

ports 

2.

TRIG OUT BNC

3.

TRIG IN BNC

4.

Exhaust fan 

5.

Power socket and 

switch 

6.

GPIB (optional) 

7.

USB device port 

Front Panel 

1

2

3

4

5

6

7

8

9

10

11

12

13

14


























































P EL -3 0 3 1 E









Description 

1.

Air inlet 

2.

LCD Display 

3.

Function keys 

4.

Power key 

5.

Main/Local key 

6.

FUNC/File key 

7.

Help/Utility key 

8.

Short key 

9.

Load On/Off 

10. Scroll wheel 

11. Number pad,

Clear/Lock and Enter 

keys 

12. USB port, Preset and

Shift keys 

13. Sense-, Sense+ 

terminals 

14. Input terminals 

Package Contents and Accessories 

Standard Accessories 

Item 

Part Number 

User /Programming Manual CD 

Quick Start Guide (this document) 

Power Cord x1 

Region Dependent 

Front terminal washers (M6) x2   61SF-062104N1 

Remote sense cables, red x1, black 

x1 

GTL-105A 

Optional Accessories 

Item 

Part Number 

GPIB cable, 2.0m 

GTL-248 

USB cable, Type A - Type B 

GTL-246 

Dust filter 

PEL-010 

Options 

Item 

Part Number 

GPIB option 

PEL-004 

This manual contains proprietary information, which is 

protected by copyright. All rights are reserved. No part 

of this manual may be photocopied, reproduced or 

translated to another language without prior written 

consent of Good Will Corporation. 
The information in this manual was correct at the time 

of printing. However, Good Will continues to improve 

its products and therefore reserves the right to change 

the specifications, equipment, and maintenance 

procedures at any time without notice.

Good Will Instrument Co., Ltd. No. 7-1, Jhongsing Rd., Tucheng 
Dist., New Taipei City 236, Taiwan.