PEL-2000B Series User Manual
142
Response speed settings will be
reflected in the Current Operation
Channel Status panel.
CVH
CH1
Slow
main
80V
CV Slow Response
CV Fast Response
Slow
Fast
Note
Changing the response speed will only affect the
current (active) channel. Other channels will not be
affected by any changes.
Select CP Mode
Background
The PEL-2000B series electronic load operates in
four different modes, Constant Current (CC),
Constant Resistance (CR), Constant Voltage (CV),
and Constant Power (CP).
CP mode cannot be used with the dedicated
Group Unit mode.
When a channel is active, the F1 key
can be used to switch between each
operating mode.
F1
F5
~
F1
Mode
CC
Mode
CR
Mode
CV
Mode
CP
Panel Operation
1.
Press the CHAN button and use
the selector knob to select a
channel.
CHAN
LOCAL
2.
Press F1 until CP mode is
displayed in the display panel.
F1
F5
~
F1
Configure
Configure
Mode
CP
Range
Low
Summary of Contents for PEL-2000B Series
Page 1: ...Programmable DC Electronic Load PEL 2000B Series USER MANUAL ISO 9001 CERTIFIED MANUFACTURER...
Page 5: ...Table of Contents 5 INDEX 312...
Page 113: ...TUTORIALS 113 14 Sound Turn the sound on off for the mainframe IU Page 202...
Page 309: ...APPENDIX 309 PEL 2004B 435 4 177 532 3 195 3 481 8 554 1 533 3 583 3...
Page 310: ...PEL 2000B Series User Manual 310 PEL 2020B PEL 2030B PEL 2040B PEL 2041B 81 6 171 2 475 446 8...
Page 317: ...INDEX 317 Wiring procedure 46...